C0240111-04-05-GB
An. In. master
N° Value
1 07.3 bar
2 12.3 °C
Display of analogue inputs 1 and 2.
An. In. master
N° Value
3 12.3 °C
Display of analogue inputs 3 and 4.
Master is only specified on units with 3 or 4 circuits.
N° Value
5 12.3 °C
6 07.3 bar
Display of analogue inputs 5 and 6.
Master is only specified on units with 3 or 4 circuits.
An. In. master
N° Value
7 05.3 °C
8 00.0
Display of analogue inputs 7 and 8.
Master is only specified on units with 3 or 4 circuits.
An. In. master
9 00.0 °C
10 A
Display of analogue inputs 9 and 10.
Master is only specified on units with 3 or 4 circuits.
An. Out. master
N° Value
1 00.0 V
2 00.0 V
Master is only specified on units with 3 or 4 circuits.
An. Out. master
N° Value
4 00.0 V
Voltage applied to analogue outputs 3 and 4.
Master is only specified on units with 3 or 4 circuits.
An. Out. master
N° Value
5 00.0 V
6 00.0 V
Voltage applied to analogue outputs 5 and 6.
Master is only specified on units with 3 or 4 circuits.
4 12.3 °C
An. In. master
N° Value
Voltage applied to analogue outputs 1 and 2.
3 00.0 V
Master is only specified on units with 3 or 4 circuits.
Mask for checking connection with the expansion cards. N means that there is
no link with the expansion indicated in the address.
Master expansions
If, for example, an expansion with address 5 must be linked and the expansion
with address 3 is configured by mistake, "...3: Y" and "...5: N". will appear
Exp.1: Y Exp.2: N
Exp.3: Y Exp.4: N
Exp.5: N
Master is only specified on units with 3 or 4 circuits.
Displays the state of the digital inputs of expansion 1 (if present) and specifies
their state.
Dig.In. master exp1
C: Contact closed
12345 67890 12345
O: Contact open
CCCCC CCCCC CCCCC
Master is only specified on units with 3 or 4 circuits.
CCC
Displays the state of the digital outputs of expansion 1 (if present) and specifies
their state.
Dig.Out. master exp1
C: Contact closed
12345 67890 12345
O: Contact open
AAAAA AAAAA AAAAA
Master is only specified on units with 3 or 4 circuits.
AAAAA AAAAA AAAA
An. In. master exp1
Displays analogue inputs 1 and 2 of expansion 1 (if present).
N° Value
Master is only specified on units with 3 or 4 circuits.
1 35.6 °C
2 40.5 °C
An. In. master exp1
Displays analogue inputs 3 and 4 of expansion 1 (if present).
N° Value
Master is only specified on units with 3 or 4 circuits.
3 37.2 °C
4 37.2 °C
Displays the state of the digital inputs of expansion 2 (if present) and specifies
their state.
Dig.In. master exp2
C: Contact closed
12345 67890 12345
O: Contact open
CCCCC CCCCC CCCCC
Master is only specified on units with 3 or 4 circuits.
CCC
Displays the state of the digital outputs of expansion 2 (if present) and specifies
their state.
Dig.Out. master exp2
C: Contact closed
12345 67890 12345
O: Contact open
AAAAA AAAAA AAAAA
AAAAA AAAAA AAAA
Master is only specified on units with 3 or 4 circuits.
An. In. master exp2
N° Value
1 04.2 bar
2 03.9 bar
Displays analogue inputs 1 and 2 of expansion 2 (if present).
Master is only specified on units with 3 or 4 circuits.
An. In. master exp2
N° Value
3 35.6 °C
4 40.5 °C
Displays analogue inputs 3 and 4 of expansion 2 (if present).
Master is only specified on units with 3 or 4 circuits.
5 22.3 °C
Displays analogue inputs 5 and 6 of expansion 2 (if present).
An. In. master exp2
N° Value
6 24.2 °C
Master is only specified on units with 3 or 4 circuits.
56
Содержание W3000 compact
Страница 7: ...C0240111 04 05 GB 7 W3000 W3000 UNIT XL UNIT B...
Страница 8: ...C0240111 04 05 GB W3000 EXPANSION E 8...
Страница 12: ...C0240111 04 05 GB Figure 3 3 mixed connection 12...