LONG TERM STORAGE
(continued from previous page)
Store the mixer in an area away from shock and vibration.
•
Once every 2-3 months, rotate the output shaft 10-20 revolutions to keep
•
the gears and bearings drying out and seizing up.
Avoid direct exposure to the sun or UV light and aggressive or corrosive
•
materials in the environment.
Drain the oil and refill the reducer with fresh oil before putting the mixer
•
back into operation.
Your mixers motor will come supplied with it's own set of operating and
•
maintenance instructions. Please follow those instructions for long term
storage of the motor.
If your mixer requires a mechanical seal, drive unit or any other
•
components supplied with a separate manufacturers operation and
maintenance manual, please follow those instructions for long term
storage of those components.
OIL FILL QUANTITY, MODEL SDM - SIDE ENTRY
MIXER MODEL
UNIT OF MEASURE
FILL QUANTITY
SDM-2
QUARTS
2.01
LITERS
1.90
SDM-3
QUARTS
3.44
LITERS
3.25
SDM-4
QUARTS
5.02
LITERS
4.75
SDM-5
QUARTS
7.93.
LITERS
7.50
SDM-6
QUARTS
12.68
LITERS
12.00
SDM-7
QUARTS
21.24
LITERS
20.00
SDM-8
QUARTS
31.71
LITERS
30.00
NOTE: SDM units do not require the use of an oil expansion chamber.
The breather plug must be positioned above the oil fill line. Cleveland
recommends changing the oil once per year.