AUTO LUBRICATOR CANISTER (KIT)
P/N APD-28301000
COVER PLATE
HARDWARE
ACTIVATION KEY
Prior to starting your mixer: screw in Auto-
Lubricator activation key and turn it
clockwise until the round plastic ring snaps
off. It's a good idea to record the date of
activation so you know when to replace
the canister.
Once the canister is activated, replace
the cover plate and secure it to the motor
adapter.
AUTO LUBRICATOR ACTIVATION
If you have an APD mixer model with a motor,
frame size 250 or larger, the input adapter will
require an auto-lubricator canister to lubricate the
input adapter bearing.
Your mixer will come supplied with a canister
factory installed. You'll need to activate the
lubricator canister prior to starting the mixer.
An auto-lubricator canister cartridge has a one
year life span. After one year of use you will need
to replace the canister. You can contact
Cleveland Mixer for replacement canisters.
EXPLOSION OF AUTO LUBRICATOR ASSEMBLY