Cleveland APD Скачать руководство пользователя страница 12

It's good to get measurements of the area around the
mixer and shaft sections to create an installation plan
prior to starting installation. Shaft sections can be long
and heavy. It works best to get them staged in the tank
prior to installing your drive unit. The use of a shaft
catcher to suspend the weight of the shaft while
lowering your drive down can be a helpful aid in
installation.

Your drive unit (reducer, motor, stub shaft and HS
couplings) will (typically) come preassembled from
the factory. It is ok to leave it assembled as you
assemble the rest of the mixer to it. Make sure to
have all of your hardware and tools handy for
connecting the mixer sections together. Torque all
the bolts to the required values to help keep the
components aligned.

ASSEMBLY OF TOP ENTRY MIXERS

The RXT and APD models are mixers that mount to the top of a tank, possibly by a
flange connection to the tank nozzle or suspended on beams above an open top
tank.

All RXT and APD models are designed and built custom to the requirements of
each individual process. It's possible the mixer you are installing will look different or
have additional or fewer components than what is shown in this manual. This
manual covers basic installation of our most common designs.

The size of your mixer is directly effected by the tank volume, tank shape, desired
level of agitation and fluid viscosity. Some mixers are supplied with a single direct
input mixing shaft and single impeller while other larger agitator set ups come with
multiple shaft sections, multiple impellers, steady bearings assemblies, etc. You can
refer to your approval drawing for the specifics of your agitator.

The following steps must be completed in order to make sure your top mounted
mixer is assembled correctly:

RXT UNIT

TOP MOUNT

Vertical shaft

APD UNIT

TOP MOUNT

Down pumping impellers

Down pumping impellers

Vertical shaft

Multiple impellers assemblies shown. These can be installed
last once the drive end and shafting are secured in place.

Be careful when assembling the impellers. Once the tank is
filled and the impellers are submerged it's not easy to get
back to these to make adjustments.

Seals are the most delicate components in the installation of
an agitator. It's very important that if you have a mechanical
seal, to follow the manufacturers installation instructions
(provided or available online). Do not rest weight on the seal,
do not suspend any of the mixer's from the seal and don't
bang the seal around. Seals have many small, delicate inner
workings that can be easily damaged.

RXT & APD AGITATOR MANUAL_09-17-15_JN

PAGE 10

Helical gearing w/
vertical mounted motor

Helical bevel
gearing w/
horizontal
mounted
motor

Содержание APD

Страница 1: ...INSTRUCTIONS FOR CLEVELAND MIXER MAINTENANCE RXT APD AGITATORS RXT O M 06 25 2015 JMN INSTALLATION OPERATION Models RXT RXTO RXTS RXTM RXT 2M Models APD APDO APDS APDM APD 2M SDM SDS...

Страница 2: ...SDM FILL QUANTITY 7 APD FILL QUANTITY 8 RXT FILL QUANTITY 9 LUBRICATION CHART 10 INSTALLATION NOTES 11 11b FIXING ELEMENT INSTALLATION 12 13 INSTALLATION NOTES 14 EXPANSION CHAMBER 15 AUTO LUBRICATOR...

Страница 3: ...oors or in a clean dry location Some mixer parts such as shaft pullers are supplied to perform future maintenance Cleveland Mixer suggest labeling these parts and putting them into storage The weight...

Страница 4: ...esigned to provide adequate rigidity and prevent loads from distorting the housing or cause misalignment of internal gears and shafts When flange mounting the mixer the bulk head plate must be enginee...

Страница 5: ...rease oil or anti seize material If fasteners cannot be lubricated use dry torque spec provided on chart Loose hardware can cause catastrophic damage It is very important to check all fasteners at sch...

Страница 6: ...ill level in accordance to the specified reducer size and mounting position Cleveland Mixer recommends an oil change 3 months after startup to flush the gear case of any debris caused by the reducer s...

Страница 7: ...the seal has been pressure tested The motor is wired to run in the correct direction with the appropriate voltage and needed amperage to run the motor The shaft and impeller assemblies are properly i...

Страница 8: ...rm storage of the motor If your mixer requires a mechanical seal drive unit or any other components supplied with a separate manufacturers operation and maintenance manual please follow those instruct...

Страница 9: ...nd up require the use of an oil expansion chamber The chamber must be installed above the oil fill level with the hose side down to allow the chamber to drain back into the reducer The fill quantities...

Страница 10: ...MODEL RXT TOP ENTRY NOTE RXT units do not require the use of an oil expansion chamber These are top entry angled helical bevel units The other mixers in this series are vertical helical units The fil...

Страница 11: ...Omala RL460 Alphasyn T460 NA Klubersynth GEM4 460N FG PAO 4 to 176 F MOBIL SHC CIBUS 460 NA NA Cassida GL460 Klubersoil 4 UH 1 460N LUBRICATION APPROVED GREASE CHART NLGI GRADE GREASE TYPE AMBIENT TEM...

Страница 12: ...mon designs The size of your mixer is directly effected by the tank volume tank shape desired level of agitation and fluid viscosity Some mixers are supplied with a single direct input mixing shaft an...

Страница 13: ...t below the lower slow speed seal of the reducer This shoulder fills the role of the snap ring used on the straight shaft 3 A stub shaft this shaft might be shouldered or straight It s a short shaft w...

Страница 14: ...ng Before inserting your mixer shaft into your gear reducer Cleveland Mixer recommends applying a lubrication compound to the insertion portion of the shaft such as Anti Seize to prevent the shaft fro...

Страница 15: ...ened around the shaft the catcher should be able to support the weight of the shaft only It is not designed to support additional weight of impellers or multiple shaft sections You might not have been...

Страница 16: ...techniques to lift and lower the drive end of the mixer to mate with the mixer shaft or mixer shaft coupling Use the fasteners supplied to make this connection before resting the weight of the drive o...

Страница 17: ...essive pressure build up minimizing the formation of foam and preventing oil loss through the breather oil seals gaskets etc As heat is released from the expanded air oil mixture contained within the...

Страница 18: ...ICATOR ACTIVATION If you have an APD mixer model with a motor frame size 250 or larger the input adapter will require an auto lubricator canister to lubricate the input adapter bearing Your mixer will...

Страница 19: ...of the tripod must be concentric with the center of the mounting flange or mount plate used to mount your mixer to the tank Use a laser to align the tripod with the mounting fixture before welding bot...

Страница 20: ...ure but with the follower and one packing ring 4 Pump the gland full of grease using the grease fitting on the side of the gland You can pump grease into the gland until you see it push through the to...

Страница 21: ...the amount of power needed to turn them The mixing power is a combination of the motor and gearbox ratings Most mixers are designed specifically to a single process Cleveland Mixer does not recommend...

Страница 22: ...e hardware will be either 316L stainless steel or zinc Stainless steel hardware should be used in sanitary or corrosive applications 3 Add a few drops of thread locker and hand tighten the nuts to the...

Страница 23: ...aled flange mounted mixers that mount to the tank with the with the mixing shaft horizontally are known as Side Entry mixers This includes Cleveland s models SDM SDS SRXTM and SRXTS The first S repres...

Страница 24: ...nd split collar that were provided with your mixer 2 Remove the cap plate and fixing element from the top of your mixers gear reducer 3 Thread the retraction rod into the top of the mixing shaft then...

Страница 25: ......

Страница 26: ...RXT APD AGITATOR MANUAL_09 17 15_JN...

Отзывы: