BNP
®
55 SUCTION BLAST CABINET
Page 25
© 2019 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 23350, Rev G, 02/19
Depending on conditions such as height and
accessibility, it may be easier to replace the baffle if the
reclaimer is removed from the cabinet.
7.10.1
Remove the flex hose from the reclaimer top.
7.10.2
Remove the fasteners securing the reclaimer
top and remove the top.
7.10.3
Remove the two bolts that secure the baffle to
the right side of the reclaimer inlet add remove the baffle
through the top.
7.10.4
Remove all caulking residue.
Figure 28
7.10.5
If removing (not replacing) the baffle, remove
the strip gasket from the inner tube, install the baffle
bolts and reclaimer top. If replacing the baffle, skip to
Paragraph 7.10.6.
7.10.6
When replacing the baffle, make sure the strip
gasket on the inner tube is in good condition and install
the new baffle in reverse order. Apply silicone caulk to
the seam (opposite side of the mounting bolts) between
the baffle and reclaimer body. Wipe the caulk smooth.
7.10.7
Inspect the strip gasket on the reclaimer upper
flange; replace it if damaged or compressed.
7.19.8
Install the reclaimer top and allow the caulking
to dry before putting the reclaimer into service.
7.11
Reverse-Pulse Dust Collector
Refer to the applicable dust-collector manual (as noted
on Page 1, Paragraph 1.1.1) for dust-collector
maintenance.
8.0
TROUBLESHOOTING
WARNING
To avoid serious injury, observe the following
when troubleshooting:
Turn OFF the compressed-air supply, Bleed
the supply line, lockout and tagout the air
supply.
When air is required to check the controls,
always enlist the aid of another person to:
Hold the blast gun securely.
Operate the foot pedal.
Never bypass the foot pedal or wedge it in
the operating position.
Never override the door interlock system.
Follow all OSHA Regulations including
lockout and tagout procedures.
8.1
Poor visibility
8.1.1
Dirty filter cartridge(s). Pulse cartridge and
empty dust container regularly. When using an RPC-2
refer to the applicable dust-collector manual noted in
Paragraph 1.1.1, to adjust pulse pressure and pulse
sequence.
8.1.2
Exhauster motor not operating. Check voltage
to motor and motor wiring.
8.1.3
Check rotation of exhauster motor; the motor
should rotate as indicated by the arrow on the housing.
If it does not rotate in the proper direction,
lockout and
tagout power
and switch the motor leads, as shown
on the motor plate. Refer to Section 2.5.
8.1.4
Using friable media that rapidly breaks down or
using media that is too fine or worn out. Check
condition of media
8.1.5
Dust-collector
damper
closed
too
far,
restricting air movement in cabinet. Adjust static
pressure, per Section 5.4.
Reclaimer Top and Inner
Tube. Style may vary.
2” Strip Gasket
2” Strip Gasket
Baffle
U-Channel
Baffle Nuts and lock washers
Baffle Bolts and
Flat Washers
Reclaimer Body