42
P1891E/EN 2014-02
1891c-enu_LCD_bedingt.fm, 25.04.2014
LCD display
7
Two-stage start button defective.
Return tool to
Sales & Service Centers
for repair.
Transducer reference voltage error
Return tool to
Sales & Service Centers
for repair.
Transducer calibration voltage error
Tool was not discharged at time of calibration.
Allow tool to discharge and try again. If this does not help:
Return tool to
Sales & Service Centers
for repair.
Transducer offset voltage error
Tool was not discharged at time of calibration.
Allow tool to discharge and try again. If this does not help:
Return tool to
Sales & Service Centers
for repair.
General collective error
Return tool to
Sales & Service Centers
for repair.
The battery is empty.
Replace the battery.
The min. torque for evaluation was not reached.
Repeat the current rundown.
Tool
Error
Start
Transd
Ref.V.
Error
Trans
CAL
Error
Trans
Off
Error
Unknow
Error
Batter
empty
-> off
No
result