1891b-enu_1_5_bedingt.fm, 25.04.2014
P1891E/EN 2014-02
19
Before initial operation
5
5.5
Changing LMC
Abb. 5-1: Changing LMC
NOTE
Electrostatically sensitive component. Note handling instructions.
The electronic assemblies of the cordless EC tool can be destroyed or damaged by electrostatic discharge
(ESD). This can lead to immediate failure, or to malfunctions at a later date. To avoid damage when chang-
ing the LMC, make sure that there is a potential equalization between the person and the tool.
Possibly set up equipment in an ESD-protected environment. Recom-
mendation for an ESD workplace: Electrically conductive work surfaces,
anti-static straps, appropriate furniture, clothing and footwear, as well as
grounding of all components.
LMC must only be changed with the battery is disconnected.
L – LiveWire 1
L – LiveWire 2
Removing LMC
Remove the battery.
Unscrew the screws (M4,
DIN 912).
Carefully pull the LMC
out of the handle and
replace it.
Inserting LMC
Carefully insert the LMC
as shown in the illustra-
tion.
Tighten the screws (M4,
DIN 912).
Insert the battery.
Graphic: CANES-