Menus and Functions
14
P2398PM | 2018-12
Apex Tool Group GmbH
3
EN
3.4.2
Run screen in the FastApps mode
Abb. 3-3: Run screen in FastApps mode
Display of the Linking group
Display of the rundown data
Symbol
Description
Display of the currently selected Linking group (FastApp).
Up to ten Linking groups can be programmed. The number on the button indicates
which Linking group is selected.
Display of the tightening strategy.
•
Display of the torque shutoff. The value to the right of the symbol indicates the
shut-off torque.
•
Display of the angle shutoff. The value to the right of the symbol indicates the shut-
off angle.
•
Display if the tightening strategy is not parameterized.
Display of the currently selected Linking group. The parameters for this Linking group
are used for the tightening.
Symbol
Description
Batch display
Number of tightening positions for a Linking group.
•
If there is only one Linking group, then each result is evaluated.
•
If there is more than one Linking group, the overall result of all the tightening posi-
tions is considered.
Example: 2/3
•
Current tightening position: 2
•
Total number of tightening positions: 3
τ
15 Nm
τ
15.7 Nm
270°
3/10
Display of the Linking group
Display of the rundown data
Change Linking group
1