91b_1_5 en bedingt.fm, 24.09.2007
P1891E/EN 09/07
19
First Operation
5
5
First Operation
5.1
Carrying out the rundown
Make sure that the battery is securely installed before operating the 47BA. The 47BA is now
ready for use. After you press and release the start button, the LCD display reads
Ready
.
Types with wireless transmission continuously communicate with the controller. The tool auto-
matically receives the parameters and, when the rundown is complete, automatically sends the
rundown results to the control system. Programming and setting up the wireless interface port
are described in the programming manual of the TMEB-200 / TMEB-COM / TMEC controller.
Types without wireless transmission must be placed in the tool holder when the rundown is com-
plete. The rundown results are transmitted and shown under the
Run screen
menu item.
5.2
Operating status
The operating modes change in the following order.
The following functions are available depending on the display:
Operating
status
LED
display
LCD display
Function
Active
Steady light:
Red – Rundown NOK
Green – Rundown OK
On
Screws
Data transmission
Automatic switch to the following after 1 minute idle time:
Energy
saver mode
Flashing light Green
Off
Data transmission
Automatic switch to the following after further 10 minutes:
Sleep
Off
Off
Data transmission not
possible
Manual switch from
Sleep
to
Active
:
Press down start button and hold down for approx. 1 second.
To switch off the 47BA manually, pull out the battery.