91b_1_5 en bedingt.fm, 24.09.2007
P1891E/EN 09/07
15
Scope of supply, transport and storage
2
Barcode not necessary as release for further rundowns
➔
From the
Scanner
tool menu, select
Read barcode
.
➔
Press the start button on the tool; this activates the barcode scanner.
The successful scan is acknowledged by an acoustic signal.
➔
Press the start button on the tool again; this starts the rundown.
Alternative: Assign the
Read barcode
function to the left function key <F1> on the tool.
➔
Press the left function key <F1> on the tool once.
➔
Press the start button on the tool again; this activates the barcode scanner.
Programming the barcode scanner is described in the programming manual of the TMEB-200 /
TMEB-COM / TMEC.
3.2.11
WLAN interface port
Tools of type 47BAW…/47BAX… are equipped with an IEEE 802.11b standard WLAN interface
port in addition to the IrDA interface port. The tool uses this WLAN interface port for continuous
communication with the controller. This interface port is used to transmit both the parameters and
the rundown results. Data transmission is possible in the
Active
,
Energy saver mode
and
Standby
operating modes, but not possible in
Sleep
(see 5.2 Operating status, page 19). Pro-
gramming and setting up the WLAN interface port are described in the programming manual of
the TMEB-200 / TMEB-COM / TMEC controller.
As the counterpart, an access point that complies with the IEEE 802.11b/g standard is required.
3.2.12
868 MHz interface port (EU)
Tools of the type 47BAR… have an 868 MHz interface port in addition to the IrDA interface port.
The tool uses this 868 MHz interface port for continuous communication with the controller. This
interface port is used to transmit both the parameters and the rundown results. Data transmission
is possible in the
Active
,
Energy saver mode
and
Standby
operating modes, but not possible in
Sleep
(see 5.2 Operating status, page 19). Programming and setting up the 868 MHz interface
port are described in the programming manual of the TMEB-200 / TMEB-COM / TMEC control-
ler.
The base station, Order no. 961300, is required as the remote station.
3.2.13
915 MHz interface port (NA)
Tools of the type 47BAF… have an 915 MHz interface port in addition to the IrDA interface port.
The tool uses this 915 MHz interface port for continuous communication with the controller. This
interface port is used to transmit both the parameters and the rundown results. Data transmission
is possible in the
Active
,
Energy saver mode
and
Standby
operating modes, but not possible in
Sleep
(see 5.2 Operating status, page 19). Programming and setting up the 915 MHz interface
port are described in the programming manual of the TMEB-200 / TMEB-COM / TMEC control-
ler.
The base station 961301 is required as the remote station.
NOTE
After the tool is switched on, it can take up to 25 seconds until the communication via WLAN is
active.