91c_LCD en bedingt.fm, 24.09.2007
P1891E/EN 09/07
27
LCD display
6
Software version on controller board
Displays the installed software version.
Software version on servo
Displays the installed software version.Displays the installed software version.
NOTE
The emergency strategy can activated only if
Emergency Strategy
has been enabled on the
TMEB-200 / TMEB-COM / TMEC under
Advanced Application
Builder\System settings
.
Emergency strategy disabled.
➔
Enable the emergency strategy on the TMEB-200 / TMEB-COM / TMEC
under
Advanced Application Builder\System set-
tings\Enable emergency strategy
.
Emergency strategy off.
If it has been enabled on the TMEB-200 / TMEB-COM / TMEC under
Advanced
Application Builder\System settings\Enable
emergency strategy
,
you can switch the emergency strategy on and off using the tool start button or
by pressing <F2> for 2 seconds. The Emergency strategy is disabled automati-
cally when the tool links to the TMEB-200 / TMEB-COM / TMEC
Emergency strategy on.
If the emergency strategy is enabled and
Linking
is disabled, the fastening
parameters of the last selected Application are used. For
Linking
operating
mode, all steps are used with the corresponding parameters of the last selected
Tightening Group.
The memory of the tool stores data from up to 512 rundowns. If more rundowns
than this are executed while the Emergency strategy is active, the oldest results
are always discarded once 512 rundowns have been recorded.
Emergency strategy
active. Is displayed during fastening.
Vers.
V1.00.
00
Servo
V:T108
N00015
Emerge
Strate
locked
Emerge
Strate
Off
Emerge
Strate
On
Emerge
Active