LCD display
6
6.2
Status display
The status display is divided into the "Standard" and "Linking" modes. "Standard" is selected if
"Linking" is not enabled on the TMEB-200 / TMEB-COM / TMEC (see
Advanced Applica-
tion Builder\Linking
). The application is selected at the Run Screen or via the App. selec-
tion inputs.
No other status messages take priority.
The tool is ready.
Number of remaining rundowns that can still be carried out until the rundown
data memory is full and the rundown data have to be transmitted to the
TMEB-200 / TMEB-COM / TMEC.
Emergency strategy
active. Is displayed if emergency strategy is currently active
and with that no communication with TMEB-200/TMEB-COM/TMEC is neces-
sary. On Tool are the latest 512 rundown results stored.
All fastening sequences have been completed.
➔
Synchronize the tool with the TMEB-200 / TMEB-COM / TMEC.
No fastening sequences have been initialized.
➔
Synchronize the tool with the TMEB-200 / TMEB-COM / TMEC.
No fastening sequence parameters have been set.
➔
Check the Application and Tightening group selected on the TMEB-200 /
TMEB-COM / TMEC to determine whether the tool settings and process
programming have been carried out.
Application locked.
➔
Synchronize the tool with the TMEB-200 / TMEB-COM / TMEC.
Reject Release active.
The tool has been programmed in
Advanced Application
Builder\Reject Release
.
➔
Depending on the programming, unlock the tool via the external input
NOK release
or Release on Backoff. To unlock via the external input
NOK
release
, set the external input and synchronize it with the TMEB-200 /
TMEB-COM / TMEC.
Ready
Remain
512
Emerge
Strate
Job
comple
Sync
No
Job
Sync
Parame
not
set
App
locked
Sync
Reject
Releas
Sync