CleanStation Dimension SRS-DT3
TM
Jet action cleaning
7. Cleaning parts
IMPORTANT:
Always wear neoprene safety gloves and eye protection while handling concentrate. Follow the instructions on the
bottle of solution concentrate from Stratasys. Please review the MSDS provided by Stratasys.
(1) Carefully open one 2.1lb bottle of WaterWorks Soluble Concentrate P400SC.
Slowly
add 1/2 of the bottle into the tank while the
pump is recirculating. If solution is not in granular form, break it up so that it can be added at a consistent rate.
ALWAYS add
concentrate to water, NEVER add water to concentrate.
(2) Wait five minutes (for most of the concentrate to dissolve).
(3) Place parts directly into the tank or basket.
(4) Check the tank periodically. If the tank level drops significantly one or two inchs due to evaporation, add more water.
DO NOT
add more cleaning solution.
(5) If the part or parts will not fit inside the basket but, will fit inside the tank, the basket can be removed from the lid by removing
the four 10-32 x 3/8” stainless screws. Reinstall the screws into the lid for later use.
8. Removing parts
IMPORTANT:
Always wear neoprene safety gloves and eye protection while removing parts from the tank.
Parts may also be removed by using stainless steel or plastic tongs.
DO NOT use aluminum tongs.
Rinse parts with water until
their surfaces do not feel slippery. Dry parts with paper towels or let air-dry.
The solution may be used for cleaning additional parts. Cleaning times are faster with fresh cleaning solution. Change the solution
whenever the water gets too dark (coffee color) or cleaning times become noticeably longer.
Operation (continued)