CleanStation Dimension SRS-DT3
TM
Jet action cleaning
Maintenance
(1) Unplug and drain the CleanStation
TM
per the Operating instruction step 10
(remember to wear safety protection).
(2) Remove and dry the tank lid before placing on another surface. If
removing the material does not increase the circulation move onto step 3.
(3) Inspect the suction strainer (see Figure 4) and remove any material
deposits. It maybe necessary to replace the strainer if the mesh becomes
excessively coated with deposits.
(4) Using a 7/16" socket, loosen (but
do not
remove) the 1/4"-20 nuts (see
Figure 4) located behind the holes at the top of the jet plate. Remove the jet
plate by lifting using the top holes provided for the 1/4”-20 nuts. As with the
tank lid, dry before setting aside.
(5) If a significant amount of material is found and removed from the suction
strainer, the manifold may not need cleaning; skip to step (9) to re-install the jet
plate. If the manifold appears to have material blocking the holes, proceed to
the next step (6) to remove and clean the manifold.
(6) Using a 5/16" socket, loosen the hose clamp connecting the manifold the
the hose and remove the 8-32 nuts with a 3/8” socket. Then completely remove
the pipe clamps and manifold (see Figure 4).
Figure 4
jet plate
strainer
• There may be a periodic need to clean the pump suction strainer or manifold that
distributes the circulating water. If you notice a significant decrease in the circulation
of water, there may be a buildup of material blocking circulation flow.
IMPORTANT:
Always
unplug the CleanStation
TM
from its power source before doing any maintenance.
Manifold
2ea 10-32 BHCS
2ea 1/4-20 nuts