Troubleshooting

If CleanStation

TM

 does not run - no power to the display.

  

Verify the power switch is turned on, the system is plugged into a

power source, and that power is available.

•  Verify adequate water level in the tank.  If water level in the tank
drops below 1 inch (approximately) from the top of the tank,
CleanStation

TM

 is designed to power itself off.

•  Check for a blown fuse.  There is one fuse located behind the tank,
facing down.  After having thoroughly drained and unplugged the
system from it's power source, tip the unit so that it's resting on it's left
side (when viewed from the front panel).  Locate the fuse (see Figure
5) looking up from the bottom of the system, behind the tank.  After
completely removing the fuse, check with an ohm meter.  A blown
fuse usually indicates some other problem …   with the system still on
it's side, spot check that all wires are undamaged.

Figure 5

main fuse

pump circuit
breaker

If CleanStation

TM

 heats with no water agitation.

•  Check for tripped pump circuit breaker.  There is a circuit breaker located behind the tank, facing down.  After having thoroughly
drained and unplugged the system from it's power source, tip the unit so that it's resting on it's left side (when viewed from the front
panel).  Locate the circuit breaker (see Figure 5) looking up from the bottom of the system, behind the tank.  The circuit breaker has
tripped if the position of the breaker switch is showing white.  Reset the breaker by pushing it in.

•  If the pump motor feels hot (to the touch), the temperature sensitive thermo switch may be tripping due to high heat.  Remove any
obstructions from the drain filter and jets (refer to the maintenance section) and allow the pump to cool down before restarting.

Содержание SRS-DT3

Страница 1: ...M facing the front provides an unobstructed view of the control panel display as well as direct access to the power switch in case quick shutdown is necessary All normal operations should be performed facing the front with the exception of accessing the drain valve which is located on the back of the CleanStationTM CleanStationTM weights approximately 63lb empty and should NEVER be moved when liqu...

Страница 2: ...Outside machine dimensions 19 1 4 inch height by 23 1 2 inch width by 21 1 2 inch depth Inside tank dimensions 10 d x 11 h x 12 1 4 w Tank holds 6 gallons of water Weight empty 63lb Power consumption 12amps at 115VAC Fuses Class G fuse Type SC 15 Ampere Operating temperature 150F ...

Страница 3: ...en proceed to the next section Operation Installation 1 Selecting a location Select a clean dry well lighted area with a minimum clearance of six inches between the CleanStationTM and any adjacent walls It is especially important to select a level surface due to liquid levels in the tank The ideal room temperatures for the system are between 65F and 80F 2 Power requirements The CleanStationTM requ...

Страница 4: ...e Also used to increase or decrease hours and minutes in the Operations Page Timer Indicator Colon blinks when timer is timing Set key Infinity key Returns to the Home Page Press and hold the Infinity Key for about 2 seconds to enter the Operations Page where hours and minutes can be changed Four Digit LED Display Lit when heater is on Pump and Heater enable indicator Lit when enabled Not used Lit...

Страница 5: ...e switch As a normal industry safety practice plug the power cord into a 115VAC ground fault interrupt outlet and turn the power switch on by pressing the left side of the switch The controller display will light The display will first show then then which is the time remaining and is also where the Home Page is located To display the current water temperature press and release on the controller s...

Страница 6: ...e water temperature at 150F recommended by Stratasys WARNING running the machine above 150F will void the warranty To change this setting the machine must be running if it is not running press to start the machine WARNING if the machine isn t running when changing temperature you may damage the heater Then press and hold and use or to select the desired temperature Parts are most efficiently clean...

Страница 7: ...k periodically If the tank level drops significantly one or two inchs due to evaporation add more water DO NOT add more cleaning solution 5 If the part or parts will not fit inside the basket but will fit inside the tank the basket can be removed from the lid by removing the four 10 32 x 3 8 stainless screws Reinstall the screws into the lid for later use 8 Removing parts IMPORTANT Always wear neo...

Страница 8: ...would be to drain the solution into a container big enough to handle the full capacity of CleanStationTM At that point mix in 270 ml of malic acid and dispose The Stratasys soluble solution is specially formulated to be safely disposed of by standard wastewater disposal procedures PM Technologies and Stratasys cannot anticipate local state or international regulatory statutes PM Technologies and S...

Страница 9: ...he tank lid dry before setting aside 5 If a significant amount of material is found and removed from the suction strainer the manifold may not need cleaning skip to step 9 to re install the jet plate If the manifold appears to have material blocking the holes proceed to the next step 6 to remove and clean the manifold 6 Using a 5 16 socket loosen the hose clamp connecting the manifold the the hose...

Страница 10: ...ligence or misuse by the Customer voids the warranty Using the machine for anything other than its intended purpose or changing anything that results in a failure also voids the warranty Changing any control parameter other than time and temperature do not exceed 150 degrees voids the warranty The Customer is expected to follow the guidelines for operations stipulated in the Installation Operation...

Страница 11: ...ck with an ohm meter A blown fuse usually indicates some other problem with the system still on it s side spot check that all wires are undamaged Figure 5 main fuse pump circuit breaker If CleanStationTM heats with no water agitation Check for tripped pump circuit breaker There is a circuit breaker located behind the tank facing down After having thoroughly drained and unplugged the system from it...

Страница 12: ...tact PM Technologies Er5 Please contact PM Technologies Machine will not stay running Check that the water level is 1 from the top of the tank Check that the suction strainer and the manifold jets are clear of debre per the maintenance instructions Technical support Telephone USA 1 763 425 1383 extension 303 Office hours 8 a m to 5 p m Monday through Friday Central Standard Time If the CleanStatio...

Страница 13: ...nty repair if machine is still under warranty for parts and labor for products purchased in the United States and Canada If the Customer s product contains features that enable PM Technologies or its authorized service representative to diagnose and repair problems with the product remotely PM Technologies may request that the Customer allow such remote access to the product In the maintenance of ...

Отзывы: