22
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Lack of pressure
(initial use)
(continued)
Choke lever is in the
OPEN position.
Set the choke lever to the OFF (right)
position.
Throttle control lever is
not set high enough.
Move the throttle control lever to left.
High pressure hose is too
long.
Make sure the high pressure hose is under
100 feet.
Will not draw
chemicals
Chemical filter is
blocked.
Clean the filter.
Chemicals being used
are too thick.
Dilute the chemicals. The chemicals
should have the consistency of water.
High pressure hose is too
long.
Use a longer supply hose instead of a very
long high pressure hose.
Chemical build up inside
the chemical injector.
Have the parts cleaned or replaced by
your dealer.
Lack of pressure
(after a period of
normal use)
Worn seal or packing.
Have them replaced by your dealer.
Worn or obstructed
valves.
Have them replaced by your dealer.
Water leaking at
the pump
Loose connections.
Tighten.
Worn or broken O-rings.
Have them replaced by your dealer.
Pump head or tubes
damaged from freezing.
Have it replaced by your dealer. See
“Storage” on page 17.
Oil leaking at the
pump
Oil seals worn.
Have them replaced by your dealer.
Worn O-rings.
Check and replace.
Water leaking
from the drain
hose
Pump is overheating
This is a safety feature and should be
expected. It cools the pump by releasing
some of the hot water within the pump
and replacing it with fresh ‘cool’ water.
Pump pulsates
Nozzle obstructed.
Clear the nozzle.