252
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
12 Faults and remedies
12.6 Separation
67088
12.6 Separation
87903
12.6.1 Separation problem and remedy
– Observe the general warnings at the beginning of
the "Trouble and remedy" chapter.
Malfunction
Cause, remedy
Straw walker
Plugging on the straw walker
• Adjust tension of straw walker drive belt.
• Remove soling (awn accumulations) on the straw
walker.
Slip reported from different units
• If necessary, check tight seat and correct position of
cam wheels.
The separation performance monitor displays insuf-
ficient performance.
• Clean sensor trough.
• Check tight seat of sensor trough and sensor.
Loose sensor trough - Tighten sensor trough.
Loose sensor - Replace sensor trough.