180
00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09
10 Fieldwork settings
10.4 Separation
67086
10.4 Separation
82550
10.4.1 Adjusting the separation performance
monitor sensors
The cleaning and separation performance monitor
allows the operator to make full use of the capacity of
the machine.
A gauge allows the operator to determine how fast the
machine can be driven without the reasonable grain
loss limit being exceeded.
Grains lost over the back of the combine with the straw
fall onto the sensors (2). The pulses generated are vis-
ualised by meter lights on a display.
The sensors (2) react with different sensitivities to dif-
ferent grain sizes and must therefore be calibrated to
the respective grain size, using switch (4).
The gauge sensitivity setting is carried out during field-
work. See Adjusting the separation performance
monitor display.
– Adjust the sensitivity of the sensors to the different
grain sizes on switch (4).
The sensors react more / less sensitively, depending
on the pre-set grain size.
12
19647
2
2
4
13
19650
4
1
3
2
Sensitivity of sensors
Position
Grain sizes
1
for lightweight grains
2
for medium-weight grains
3
for heavy grains