283
13 Maintenance
13.5 Engine
67089
- To do this, turn out the shut-off tap (1).
86095
13.5.10 Bleed fuel system
– Observe the general warnings at the beginning of
the "Maintenance" chapter.
– Observe the information provided in the operator's
manual of the engine manufacturer.
Venting the fuel system (hand pump)
– Slacken off bolt of (1) by turning it anti-clockwise.
– Actuate pump by pumping movements at bolt (1).
The system is vented when the pump resistance is
noticeably increased.
– Turn in screw (1).
Venting the fuel system (electric pump)
– Turn on the ignition –
Do not start the diesel
engine.
With the ignition turned on, the fuel feed pump (1) is
ON and vents the fuel system automatically.
– Switch off the ignition again after some minutes or
start the diesel engine.
86098
13.5.11 Cleaning the fuel sediment bowl filter
The fuel sediment bowl cleans the fuel before it enters
the fuel feed pump.
– Observe the general warnings at the beginning of