© 1999-2017 Citrix Systems, Inc. All rights reserved.
p.212
https://docs.citrix.com
3. Verify that the replacement solid-state drives (SSDs) are the ones required for your NetScaler model. The conversion
requires minimum of four SSDs. The Citrix label is on the top of one of the solid-state drives, which is pre-populated with a
new version of BIOS and a recent build of the required NetScaler SDX Management Service. This SSD must be installed in
slot # 1.
4. Remove the SSDs by pushing the safety latch of the drive cover down while pulling the drive handle.
5. On the new Citrix Certified SSD drive, open the drive handle completely to the left, and then insert the new drive into the
slot #1 as far as possible.
6. To seat the drive, close the handle flush with the rear side of the appliance so that the drive locks securely into the slot.
Important: The orientation of the SSD is important. When you insert the drive, make sure that the Citrix product label is at
the top.
7. Insert a second Citrix certified SSD, which matches the capacity of the SSD in slot #1, in slot # 2. Insert additional blank
Citrix certified SSDs in slots #3 and #4.
Note: If the license of your appliance is 14040, insert additional blank Citrix certified SSDs in slots #3, #4, #5, and #6.
If the license of your appliance is 14060/14080/14100, insert additional blank Citrix certified SSDs in slots #3, #4, #5, #6, #7,
and #8.
Important: Note that mixing and matching of old and new SSDs is not supported. SSDs in slot #1 and slot # 2, which
constitute the first RAID pair (local storage), must be of same size and type. Similarly, SSDs in slot # 3 and slot # 4, which
constitute the second RAID pair (VPX storage), must be of same size and type. Do not use any other drives that are not
part of the provided conversion kit.
8. Store the old SSDs for future handling.
9. Disconnect all network cables from the data ports and the management ports.
10. Start the NetScaler appliance. For instructions, see “Switching on the Appliance” in
.
The conversion process can run for approximately 30 minutes, during which you must not power cycle the appliance. The
entire conversion process might not be visible on the console and might appear to be unresponsive.
The conversion process updates the BIOS, installs the XenServer hypervisor and the Management Service Operating
system, and copies the NetScaler VPX image to the SSD for instance provisioning, and forms the Raid1 pair.
Note: The serial number of the appliance remains the same.
Содержание NetScaler SDX 11500
Страница 90: ...1999 2017 Citrix Systems Inc All rights reserved p 90 https docs citrix com 5 Click OK...
Страница 218: ...1999 2017 Citrix Systems Inc All rights reserved p 218 https docs citrix com...
Страница 235: ...1999 2017 Citrix Systems Inc All rights reserved p 235 https docs citrix com...
Страница 253: ...1999 2017 Citrix Systems Inc All rights reserved p 253 https docs citrix com errorcode 1 message IP address is missing...