The following components are visible on the back panel of the MPX 25100TA, MPX 25160TA, and MPX
25200TA appliance:
• One 300 GB removable solid-state drives. These appliances are a redundant array of indepen-
dent disks (RAID) devices. In a RAID configuration, the same data is stored on multiple drives to
improve performance, increase storage capacity, lower the risk of data loss, and provide fault
tolerance. The two SSDs store the same data. If one fails and you replace it, the new SSD mirrors
the other one.
• Power switch, which turns power to the appliance on or off. Press the switch for less than two
seconds to turn off the power.
• Two power supplies, each rated at 1000 watts, 100–240 volts. Max power consumption is 717 W.
Typical power consumption is 594 W. Each power supply has an LED that indicates the status of
the power supply, as described in
.
• Disable alarm button, which is functional only when the appliance has two power supplies.
Press this button to stop the power alarm from sounding when:
–
You have plugged the appliance into only one power outlet
–
One power supply is malfunctioning and you want to continue operating the appliance
until it is repaired.
• Non-maskable interrupt (NMI) Button, used at the request of Technical Support to initiate a core
dump. To press this red button, which is recessed to prevent unintentional activation, use a pen,
pencil, or other pointed object. The NMI Button is also available remotely over the network in
the LOM GUI, in the Remote Control menu. For more information about the lights out manage-
ment port of the appliance, see
Lights out management port of the Citrix ADC MPX appliance
.