Citrix ADC MPX
5. Wait for the upgrade process to complete. The appliance automatically reboots after the up-
grade is complete.
Upgrade the appliances in a high availability setup
Perform the following steps:
1. Log on to the secondary node and upgrade it as described in
Upgrade a standalone appliance
.
2. Force a high availability failover. The secondary node is now the primary node. The primary
node becomes secondary.
3. Log on to the new secondary (old primary) node and upgrade it as described in
Upgrade a stan-
dalone appliance
.
Hardware health attributes
July 19, 2019
Operating ranges for Citrix ADC hardware platforms vary for different attributes.
Note
: Use the
stat system
-
detail
command to display the current values of the attributes.
Health attributes for MPX 5500/7500/9700/9700 10G platform
The following tables list the health attributes and their recommended value ranges.
Health
attributes/-
Platform
SNMP Alarm
Support
MPX
5500/5600
MPX
7500/9500
MPX
9700/10500/12500/15500
MPX
9700/10500/
12500/15500
10G
CPU 0 core
(Volts)
No
0.97–1.5
1–1.5
1–1.5
1–1.5
CPU 1 core
(Volts)
No
0.97–1.5
1–1.5
1–1.5
1–1.5
Main 3.3 V
Supply (Volts)
Yes
3.2–3.6
3.2–3.54
3.2–3.54
3.2–3.55
Standby 3.3 V
Supply (Volts)
Yes
3.2–3.6
3.2–3.54
3.2–3.54
3.2–3.55
© 1999-2019 Citrix Systems, Inc. All rights reserved.