5. Verify the replacement drive is recognized.
1
root@ns
#
atacontrol status ar0
Output:
1
ar0
:
ATA RAID1 status
:
DEGRADED
2
subdisks
:
3
0
ad4
SPARE
4
1
ad6
ONLINE
6. Start the rebuild process.
1
root@ns
#
atacontrol rebuild ar0
7. Monitor the rebuild process.
1
root@ns
#
atacontrol status ar0
Output:
1
ar0
:
ATA RAID1 status
:
REBUILDING
10%
completed
2
subdisks
:
3
0
ad4
SPARE
4
1
ad6
ONLINE
Note:
Rebuilding the RAID array takes some time.
8. Verify the REBUILD is successful.
1
root@ns
#
atacontrol status ar0
Output:
1
ar0
:
ATA RAID1 status
:
READY
2
subdisks
:
3
0
ad4
ONLINE
4
1
ad6
ONLINE
Note:
After the rebuild operation completes, the subdisks status shows ONLINE and the RAID
status shows READY.
9. Exit the shell and verify the status of the RAID array from the Citrix ADC CLI.
1
root@ns
#
exit
2
>
sh raid
© 1999-2019 Citrix Systems, Inc. All rights reserved.