Chapter 5 Maintaining the Router
Removing and Replacing the Standard AC-Input Power Shelf
5-22
Cisco XR 12416 and Cisco XR 12816 Router Chassis Installation Guide
OL-17440-01
Step 5
Insert the new power shelf halfway into the chassis.
Step 6
Connect the power shelf to the chassis power interface panel connectors
(
Figure 5-15
):
a.
Be sure the holes on each side of the power shelf are aligned with the guide
pins on each side of the chassis.
b.
Carefully slide the power shelf into place until its two connectors just mate
with the power interface panel connectors.
Caution
To prevent damage to the interface connectors, do not use excessive force when
inserting the power shelf into the chassis.
Figure 5-15
Connecting the AC-Input Power Shelf
28021
Hole
Guide pin
(one on each
side of chassis)
Elcon connectors
on power shelf
back panel