Chapter 6 Troubleshooting the System Hardware
Symptoms and Solutions
6-42
Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
OL-15012-02
A hard disk drive was not
detected while the operating
system was being started.
Reseat all hard disk drives and cables. Run the hard disk drive
diagnostic tests again.
A hard disk drive passes the
diagnostic Fixed Disk Test,
but the problem remains.
Run the diagnostic SCSI Attached Disk Test.
Table 6-12
General Problems
Symptom
Cause and Action
Problems such as broken cover
locks or indicator LEDs not
working.
Broken component. Call your customer service representative.
Table 6-13
Intermittent Problems
Symptom
Cause and Action
A problem occurs only
occasionally and is difficult to
detect.
1.
Verify the following items:
a.
All cables and cords are connected securely to the rear of the
device and attached hardware options.
b.
When the device is powered on, air is flowing from the rear
of the device at the fan grille. If there is no airflow, the fans
are not working. This causes the device to overheat and shut
down.
2.
Check the system error log.
3.
See the
“Undetermined Problems” section on page 6-21
.
Table 6-11
Hard Disk Drive Problems (continued)
Symptom
Cause and Action
Содержание WAE-674-K9 - Wide Area Application Engine 674