A-2
Cisco UCS C3160 Rack Server Installation and Service Guide
OL-22326-01
Appendix A Server Specifications
Environmental Specifications
Environmental Specifications
Table A-2
lists the environmental specifications for the server.
Power Specifications
Table A-3
lists the specifications for each 1050 W power supply (Cisco part number UCSC-C3X60-PSU).
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Table A-2
Environmental Specifications
Description
Specification
Temperature, operating
5ºC to 35ºC (41ºF to 95ºF)
Temperature, nonoperating
–40ºC to 65ºC (–40ºF to 149ºF)
Humidity, operating
10% to 90% non-condensing
Humidity, nonoperating
5% to 93% non-condensing
Altitude, operating
Derated 1ºC for each 305 m
0 m to 3048 m (0 ft to 10,000 ft)
Altitude, nonoperating
0 m to 12,192 m (0 ft to 40,000 ft)
Acoustic noise, operating
LWAd 5.4 Bel
LpAm 38 dBA
Table A-3
1050 W Power Supply Specifications
Description
Specification
Class
RSP2
AC input voltage
100 to 240 VAC nominal (Range: 90 to 264 VAC)
AC input frequency
47 to 63 Hz nominal (Range: 47 to 63 Hz)
AC line current (steady state)
12.5 A maximum at 100 VAC
6.0 A maximum at 208 VAC
AC line inrush current
15 A peak at 35ºC, 208 VAC
Maximum output power for each power
supply
1050 W on main power
30 W on standby power
Power supply output voltage
Main power: 12 VDC
Standby power: 12 VDC
Rated output load
Main power: 87.5 DC Amps (at 180-264 VAC),
66.67 DC Amps (at 90-180 VAC)
Standby power: 2.5 DC Amps
Содержание UCS C3160
Страница 6: ...Contents vi Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 10: ...x Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 12: ...xii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 13: ...xiii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...