3-3
Cisco UCS C3160 Rack Server Installation and Service Guide
OL-32062-01
Chapter 3 Maintaining the System
Status LEDs and Buttons
3
System status
•
Green—The system is running in normal operating condition.
•
Green, blinking—The system is performing system initialization and memory
check.
•
Amber, steady—The system is in a degraded operational state. For example:
–
Power supply redundancy is lost.
–
CPUs are mismatched.
–
At least one CPU is faulty.
–
At least one DIMM is faulty.
–
At least one drive in a RAID configuration failed.
•
Amber, blinking—The system is in a critical fault state. For example:
–
Boot failed.
–
Fatal CPU and/or bus error is detected.
–
System is in an over-temperature condition.
4
Fan status
•
Green—All fan modules are operating properly.
•
Amber, steady—One fan module has failed.
•
Amber, blinking—Critical fault; two or more fan modules have failed.
5
Temperature status
•
Green—The system is operating at normal temperature.
•
Amber, steady—One or more temperature sensors have exceeded a warning
threshold.
•
Amber, blinking—One or more temperature sensors have exceeded a critical
threshold.
6
Power supply status
•
Green—All power supplies are operating normally.
•
Amber, steady—One or more power supplies are in a degraded operational state.
•
Amber, blinking—One or more power supplies are in a critical fault state.
7
Network link activity
•
Off—The Ethernet link is idle.
•
Green—One or more Ethernet LOM ports are link-active.
•
Green, blinking—One or more Ethernet LOM ports are traffic-active.
8
Internal-drive status LEDs
Use these LEDs to indicate the location of a failing drive. Then open the system cover
to find exactly which drive is failing by looking at the LEDs on the drive trays.
•
The two columns of LEDs correspond to the two halves of the internal drive
compartment (under either the right- or left-side top cover).
•
The four numbered rows of LEDs correspond to the four horizontal rows of drive
bays (14 drive bays in each row).
See
Figure 3-9
for an example. In this example, the red LED indicates that the failing
drive is in the right half of the internal drive compartment, in row 3.
Table 3-1
Front-Panel LEDs States (continued)
LED Name
State
Содержание UCS C3160
Страница 6: ...Contents vi Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 10: ...x Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 12: ...xii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 13: ...xiii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...