3-37
Cisco UCS C3160 Rack Server Installation and Service Guide
OL-32062-01
Chapter 3 Maintaining the System
Installing or Replacing System Components
c.
Apply thermal grease from the syringe that is included with the new CPU to the top of the CPU.
Apply about half the syringe contents to the top of the CPU in the pattern that is shown in
Figure 3-23
.
Note
If you do not have a syringe of thermal grease, you can order a spare
(Cisco PID UCS-CPU-GREASE3).
Figure 3-23
Thermal Grease Application Pattern
d.
Align the heatsink captive screws with the motherboard standoffs, and then use a Number 2
Phillips-head screwdriver to tighten the captive screws evenly.
Note
Alternate tightening each screw evenly to avoid damaging the heatsink or CPU.
Step 11
Replace the server node cover as described in
Removing the Server Node Cover, page 3-12
.
Step 12
Install a server node:
a.
With the two ejector levers open, align the new server node with the empty bay.
Note
The server node must be in the top bay, as shown in
Figure 1-2 on page 1-2
.
b.
Push the server node into the bay until it engages with the midplane connectors and is flush with the
chassis.
c.
Rotate both ejector levers toward the center until they lay flat and their latches lock into the rear of
the server node.
Step 13
Replace power cords and then power on the system by pressing and holding the power button on the front
handle for four seconds.
334295
Содержание UCS C3160
Страница 6: ...Contents vi Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 10: ...x Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 12: ...xii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...
Страница 13: ...xiii Cisco UCS C3160 Rack Server Installation and Service Guide OL 32062 01 ...