Important Safety Instructions
78-4015908-01 Rev F
xiii
Note:
If this plug cannot be fully inserted into the outlet, try reversing the plug.
If the plug still fails to fit, contact an electrician to replace the obsolete 2-terminal
outlet.
Grounding Terminal
If this equipment is equipped with an external grounding terminal, attach one end of
an 18-gauge wire (or larger) to the grounding terminal; then, attach the other end of
the wire to a ground, such as a grounded equipment rack.
Safety Plugs (European Union)
Class I Mains Powered Equipment
– Provided with a 3-terminal AC inlet and
requires connection to a 3-terminal mains supply outlet via a 3-terminal power
cord for proper connection to the protective ground.
Note:
The equipotential bonding terminal provided on some equipment is not
designed to function as a protective ground connection.
Class II Mains Powered Equipment
– Provided with a 2-terminal AC inlet that
may be connected by a 2-terminal power cord to the mains supply outlet. No
connection to the protective ground is required as this class of equipment is
provided with double or reinforced and/or supplementary insulation in
addition to the basic insulation provided in Class I equipment.
Note:
Class II equipment, which is subject to EN 50083-1, is provided with a
chassis mounted equipotential bonding terminal. See the section titled
Equipotential Bonding
for connection instructions.
Equipotential Bonding
If this equipment is equipped with an external chassis terminal marked with the IEC
60417-5020 chassis icon ( ), the installer should refer to CENELEC standard EN
50083-1 or IEC standard IEC 60728-11 for correct equipotential bonding connection
instructions.
AC Power
Important:
If this equipment is a Class I equipment, it must be grounded.
If this equipment plugs into an outlet, the outlet must be near this equipment,
and must be easily accessible.
Connect this equipment only to the power sources that are identified on the
equipment-rating label normally located close to the power inlet connector(s).
This equipment may have two power sources. Be sure to disconnect all power
sources before working on this equipment.
If this equipment
does not
have a main power switch, the power cord connector
serves as the disconnect device.
Содержание Prisma II
Страница 1: ...78 4015908 01 Rev F Prisma II High Density Dual Reverse Receiver Installation and Operation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ......
Страница 36: ......
Страница 67: ...ICIM2 Front Panel 78 4015908 01 Rev F 43 ICIM2 Front Panel ICIM2 Illustration Front Panel ...
Страница 106: ...Chapter 4 Operation using LCI 82 78 4015908 01 Rev F Prisma II XD Chassis Top Right Corner Detail ...
Страница 124: ......
Страница 130: ......
Страница 138: ......