Chapter 3 Operation using ICIM
42
78-4015908-01 Rev F
Important:
Do not operate any Prisma II Chassis without a fan tray installed properly. If a
fan tray is not installed in the Prisma II Chassis, the ICIM will not communicate
with any of the modules in that chassis.
All chassis connected in a daisy-chain must be powered and have a fan tray
installed. A chassis that is connected but is either not powered, or does not have
a fan tray installed will cause faulty operation of the ICIM.
All chassis connected in this daisy-chain must have a unique chassis
identification (ID) number.
The last chassis in the daisy-chain must have a terminator installed in the ICIM
OUT connector. Otherwise, faulty communication with the ICIM may occur.
ICIM Block Diagram
A block diagram representing the ICIM2 or ICIM2-XD is shown below.
Prisma II Standard / XD Chassis
ICIM2 / ICIM2-XD
Module
Microprocessor
Ethernet
CLI
Hardware
Interface
Hardware
Interface
Hardware
Interface
RS-232
RJ-45
ICIM
In
Backplane /
Midplane
Bus
Connection
DB-9
DB-9
ICIM
Out
Configuration & Monitoring Bus
TP514
LCD
Keypad
(Absent from ICIM2-XD)
Содержание Prisma II
Страница 1: ...78 4015908 01 Rev F Prisma II High Density Dual Reverse Receiver Installation and Operation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ......
Страница 36: ......
Страница 67: ...ICIM2 Front Panel 78 4015908 01 Rev F 43 ICIM2 Front Panel ICIM2 Illustration Front Panel ...
Страница 106: ...Chapter 4 Operation using LCI 82 78 4015908 01 Rev F Prisma II XD Chassis Top Right Corner Detail ...
Страница 124: ......
Страница 130: ......
Страница 138: ......