Appendix A
Module Parameter Descriptions
112
78-4015908-01 Rev F
Receiver Alarm Data Parameters
Parameter
Name (LCI)
ICIM
Abbreviation
Nominal
Value
Major
Low
Limit
Minor
Low
Limit
Minor
High
Limit
Major
High
Limit
Hysteresis Operating
Range
Rx 1 Nominal
Input
InPwr1
1
-18.0 to
2.0 dBm in
0.5 step
-20
-4
3.2
3.2
1
OK or
Alarm
Rx 2 Nominal
Input
InPwr2
1
-18.0 to
2.0 dBm in
0.5 step
-20
-4
3.2
3.2
1
OK or
Alarm
Power
Supply Status
PsOk
-
-
-
-
-
-
OK or
Alarm
Forced Alarm
Status
Alarm
-
-
-
-
-
-
OK or
Alarm
Forced Alarm
Rx1 Status
2
Alarm1
-
-
-
-
-
-
OK or
Alarm
Forced Alarm
Rx2 Status
2
Alarm2
-
-
-
-
-
-
OK or
Alarm
AGC 1 Range
Status
AGC1Rng
-
-
-
-
-
-
OK or
Alarm
AGC 2 Range
Status
AGC2Rng
-
-
-
-
-
-
OK or
Alarm
CAN Bus
Status
2
CANBus
-
-
-
-
-
-
OK or
Alarm
Redundant
Receiver 1
Alarm
2
RedRx1
-
-
-
-
-
-
OK or
Alarm
Redundant
Receiver 2
Alarm
2
RedRx2
-
-
-
-
-
-
OK or
Alarm
1
InPwr1 and InPwr2 values are reported to five decimal places, but for practical purposes,
only the first two digits should be regarded as significant.
2
Visible in LCI in Independent mode only.
Содержание Prisma II
Страница 1: ...78 4015908 01 Rev F Prisma II High Density Dual Reverse Receiver Installation and Operation Guide ...
Страница 2: ......
Страница 10: ......
Страница 20: ......
Страница 22: ......
Страница 24: ......
Страница 36: ......
Страница 67: ...ICIM2 Front Panel 78 4015908 01 Rev F 43 ICIM2 Front Panel ICIM2 Illustration Front Panel ...
Страница 106: ...Chapter 4 Operation using LCI 82 78 4015908 01 Rev F Prisma II XD Chassis Top Right Corner Detail ...
Страница 124: ......
Страница 130: ......
Страница 138: ......