S e n d f e e d b a c k t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
1-7
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring VSAN Trunking
Default Settings
The following example shows how to display the trunk mode of a Fibre Channel interface:
switch#
show interface fc3/3
fc3/3 is up
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:83:00:0d:ec:6d:78:40
Peer port WWN is 20:0c:00:0d:ec:0d:d0:00
Admin port mode is auto,
trunk mode is on
...
The following example shows how to display the trunk protocol of a Fibre Channel interface:
switch#
show trunk protocol
Trunk protocol is enabled
The following example shows how to display the VSAN information for all trunk interfaces:
switch#
show interface trunk vsan 1-1000
fc3/1 is not trunking
...
fc3/11 is trunking
Belongs to san-port-channel 6
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
...
san-port-channel 6 is trunking
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
Default Settings
lists the default settings for trunking parameters.
Table 1-2
Default Trunk Configuration Parameters
Parameters
Default
Switch port trunk mode
On
Allowed VSAN list
1 to 4093 user-defined VSAN IDs
Trunking protocol
Enabled