Chapter 1 Configuring VSAN Trunking
Configuring VSAN Trunking
Figure 1-4
Default Allowed-Active VSAN Configuration
You can configure a selected set of VSANs (from the allowed-active list) to control access to the VSANs
specified in a trunking ISL.
Using
as an example, you can configure the list of allowed VSANs on a per-interface basis
). For example, if VSANs 2 and 4 are removed from the allowed VSAN list of ISLs
connecting to switch 1, the operational allowed list of VSANs for each ISL would be as follows:
•
The ISL between switch 1 and switch 2 includes VSAN 1 and VSAN 3.
•
The ISL between switch 2 and switch 3 includes VSAN 1 and VSAN 2.
•
The ISL between switch 3 and switch 1 includes VSAN 1, 2, and 5.
Consequently, VSAN 2 can only be routed from switch 1 through switch 3 to switch 2.