2-7
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 2 BPX Switch Physical Overview
Service Expansion Shelf PNNI
Service Expansion Shelf PNNI
The Cisco BPX SES PNNI Controller is an optional Service Expansion Shelf (SES) controller connected
directly to a BPX 8600 series switch to provide Private Network to Network Interface (PNNI) signaling
and routing for the establishment of ATM switched virtual circuits (SVCs) and Soft Permanent Virtual
Circuits (SPVCs) over a BPX 8600 wide area network. However, the SES can be used in several WAN
switching applications and is not limited to function only as a BPX SES PNNI Controller.
BPX-BXM-622
BPX-BXM-622-2
OC-12 card with 1or 2 OC-12/STM-4 ports. Card is configured for use in either
network interface or service access (UNI) mode.
Front
BPX-BME
Used for multicast connections. Used with SMF-622-2 back card with port 1
looped to port 2, transmit to receive, and receive to transmit.
BPX-SMF-622
BPX-SMFLR-622
BPX-XLR-622-BC
Back cards for BXM-622. The XLR card supports a 1500nm interface.
Back
BPX-SMF-622-2-BC
BPX-SMFLR-622-2-BC
BPX-SMFLR-622-2-BC
Back cards for BXM-622-2 and BME (BME typically would use SMF-622-2).
Back
BPX-BME
Used for multicast connections. Used with SMF-622-2 back card with port 1
looped to port 2, transmit to receive, and receive to transmit.
Back
BPX-BNI-3-T3
Broadband Network Interface Card (with 3 T3 Ports).
Front
BPX-T3-BC
Line Module, used with BNI-T3 for 3 physical T3 ports. (Configured for 3 ports) Back
BPX-BNI-3-E3
Broadband Network Interface Card (with 3 E3 Ports).
Front
BPX-E3-BC
Line Module, used with BNI-E3 for 3 physical E3 ports. (Configured for 3 ports). Back
APS Back Cards and APS Redundant Backplane
The APS 1+1 feature requires two BXM front cards, an APS redundant frame assembly, and two redundant type BXM back
cards. The following are the types of redundant back card and backplane sets:
•
BPX-RDNT-LR-155-8 (8 port, long reach, SMF, SC connector)
•
BPX-RDNT-LR-622 (single port, long reach, SMF, FC connector)
•
BPX-RDNT-SM-155-4 (4 port, medium reach, SMF, SC connector)
•
BPX-RDNT-SM-155-8 (8 port, medium reach, SMF, SC connector)
•
BPX-RDNT-SM-622 (single port, medium reach, SMF, FC connector)
•
BPX-RDNT-SM-622-2 (2 port, medium reach, SMF, FC connector)
Each of the listed model numbers includes two single back cards and one mini-backplane.
Service Interface Component Group
BPX-E3-BC
Line Module, used with BNI-E3 for 2 physical E3 ports. (Configured for 2 ports) Back
Power Supply Group
48 Volt DC Power Supply
Optional AC Power Supply
Table 2-1
BPX Switch Plug-In Card Summary (continued)
Card
Card Name
Location
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......