23-13
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 23 Configuring BXM Virtual Switch Interface
VSI Configuration Procedures
To add a PNNI controller, use the following procedure:
Step 1
Up a trunk interface by using the
uptrk
command.
Step 2
Configure resource on the trunk interface for the PNNI controller's control channels by using the
cnfrsrc
command.
Step 3
Add the SES PNNI to the BPX and enable AnnexG protocol to run between the BPX and the SES by
using the
addshelf
command with feeder type set to “X”.
Step 4
Enable the VSI capabilities on the trunk interface by using the
addctrlr
command.
Viewing Controllers and Interfaces
Display commands such as
dspnw
and
dspnode
show interface shelves.
To view conditions on an interface shelf (feeder) trunk, use the
dspnode
command to identify the hub
and interface shelf (feeder) nodes and shows the alarm status.
To view conditions of VSI controllers, use the
dspctrlrs
command to display all VSI controllers attached
to the BPX. The VSI controllers are either a PNNI controller or an MPLS controller.
The designation for an Multiprotocol Label Switching (MPLS) controller serving as an interface shelf is
LSC.
The external network management system can query the BPX via SNMP to discover VSI controller IDs
and IP addresses.
Deleting a Controller
To delete a controller or interface (feeder) shelf, first delete it from the network. Then down the port and
trunk. This applies to MPLS controllers or generic VSI controllers that do not need AnnexG protocols.
To delete an MPLS controller, use the following procedure.
Step 1
Delete an MPLS controller from a BPX node by using the
delshelf
command.
Step 2
Down the port by using the
dnport
command.
or
Step 3
Down the trunk by using the
dntrk
command.
To delete a PNNI controller, use the following procedure:
Step 1
Delete the VSI capabilities on the trunk interface by using the
delctrlr
command.
Step 2
Delete the SES attached to the trunk interface by using the
delshelf
command.
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......