7-6
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 7 Preliminary Steps Before Installing
Mechanical Installation
Mechanical Installation
Caution
If the BPX switch is to be mounted in an enclosed cabinet, ensure that a free flow of air in and out
of the enclosure is provided. Contact Cisco Customer Service for further information.
Horizontal Positioning
BPX switch shelves are designed to be mounted to two sets of vertical mounting rails in either a Cisco
cabinet or a standard 19-inch equipment rack with unrestricted front to rear air flow. When installed in
a Cisco cabinet (see Figure 7-2), the front flanges of the BPX switch are secured to the front rails of the
Cisco cabinet. In factory installations, rear support is provided by rear mounting rails in the cabinet at a
setback of 19.86 inches. As an option, a rear set of rails located at a setback of approximately 30 inches
may be used for rear support.