Chapter 28 Troubleshooting
Troubleshooting the BPX Switch
System Troubleshooting Tools
You can perform a number of manually initiated tests from the Cisco WAN Manager NMS console to
assist in system troubleshooting. These tests may be included in a job so they can be scheduled to run
remotely at a specified time if desired.
User-Initiated Tests
Several user-initiated tests can be used to diagnose system problems. These tests are self-contained in
that they do not require the use of external test equipment. They also do not require you to place a
loopback at the far end to test both directions of transmission. The user initiated tests are listed in
Table 28-3.
Several display commands can be used to obtain information that may be helpful in troubleshooting
system problems. The system troubleshooting commands are also listed in Table 28-3.
All card types
(continued)
Unavailable
Card is present but it may be in one of the following states:
1.
The node does not recognize the card.
2.
The card is running diagnostics.
Down
Downed card.
Empty
No card in that slot.
BCC
Same status as for all card types, plus:
Updating
Standby BCC downloading the network configuration from an
active BCC.
Note:
Red FAIL LED flashes during updating.
Cleared
BCC is preparing to become active.
Downloading
Software
There are downloader commands that appear when the system
is down loading software to the BCC.
Minor
BCC Redundancy alarm indicates node is configured for
redundancy but no standby BCC is equipped.
1.
Cards with an F status (no terminal failure) are activated only when necessary. Cards with a failed status are never activated.
Table 28-2 Card Status for the BPX Switch (continued)
Card Type
Status
1
Description
Table 28-3 System Troubleshooting Commands Available
Command
Description
Test Connection (
tstcon
)—Frame
Relay
Performs a bidirectional test of the specified Frame Relay connection or range of
connections by inserting a test pattern and comparing the returned pattern with the
pattern transmitted. A pass or fail indication appears next to the tested connection
in the Display Connections screen.
Test Connection (
tstcon
)—data
Same as above except for synchronous data connections.
Test Connection (
tstcon
)—voice
Same as above except for voice connections.
Test Delay (
tstdelay
)—Frame Relay
Measures the round-trip delay over the selected Frame Relay connection.
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......