13-8
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 13 Installing the BPX Switch Cards
Verifying 9.6 or 19.2 Gbps Backplane
Figure 13-6 Card slot and fan fuses, identifying the 19.2 Gpbs backplane
If the BPX Switch is a late model, then a 19.2 Gbps backplane is installed. You can verify this by running
the
dspbpnv
command, which will display “Word #2 =0001” if the backplane NOVRAM has been
programmed. If anything else is displayed, you’ll have to visually check the backplane for the fuses. For
information about the bit fields used for the BCC backplane NOVRAM format, see the
Cisco WAN
Switching Command Reference, Release 9.3.30
.
If the backplane is a 19.2 Gbps backplane, but the backplane NOVRAM has not been set to display Word
#2 =0001, you can use the
cnfbpnv
command to program the NOVRAM.
To program the NOVRAM with the
cnfbpnv
command, use the following procedure:
Step 1
Enter
cnfbpnv
command to configure the backplane. The following message appears as an
acknowledgement:
Are you sure this is a new backplane (y/n).
Step 2
Enter
y
to continue.
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
F4
F5
F6
F7
F8
F9 F10 F11 F12 F13 F14 F15 F16 F17 F18
Card slots
F1
F2
F3
H8037
Fan
Fuses
(F4, for card slot 15)
(F18, for card slot 1)
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......