General Information

1

Years of networking experience:

Years of experience with Cisco products:

2

I have these network types:

LAN

Backbone

WAN

Other:

3

I have these Cisco products:

Switches

Routers

Other (specify models):

4

I perform these types of tasks:

H/W installation and/or maintenance

S/W configuration

Network management

Other:

5

I use these types of documentation:

H/W installation

H/W configuration

S/W configuration

Command reference

Quick reference

Release notes

Online help

Other:

6

I access this information through:

% Cisco.com

% CD-ROM

% Printed manuals

% Other:

7

I prefer this access method:

Cisco.com

CD-ROM

Printed manuals

Other:

8

I use the following three product features the most:

Document Information

Document Title:  Catalyst 3750 Switch Hardware Installation Guide

Part Number:

78-15136-03

S/W Release (if applicable): 

 

On a scale of 1–5 (5 being the best), please let us know how we rate in the following areas:

The document is complete.

The information is accurate.

The information is well organized.

The information I wanted was easy to find.

The document is written at my
technical level of understanding.

The information I found was useful to my job.

Please comment on our lowest scores:

Mailing Information

Organization

Date

Contact Name

Mailing Address

City

State/Province

Zip/Postal Code

Country

Phone (

)

Extension

E-mail

Fax

(

)

May we contact you further concerning our documentation?

Yes

No

You can also send us your comments by e-mail to 

[email protected]

, or by fax to 

408-527-8089

.

When mailing this card from outside of the United States, please enclose in an envelope addressed to the location on the back of this card with 
the required postage or fax to 1-408-527-8089.

Содержание 3750 - Catalyst EMI Switch

Страница 1: ...nuals Other 7 I prefer this access method Cisco com CD ROM Printed manuals Other 8 I use the following three product features the most Document Information Document Title Catalyst 3750 Switch Hardware Installation Guide Part Number 78 15136 03 S W Release if applicable On a scale of 1 5 5 being the best please let us know how we rate in the following areas The document is complete The information ...

Страница 2: ... L A S S M A I L P E R M I T N O 4 6 3 1 S A N J O S E C A POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES DOCUMENT RESOURCE CONNECTION CISCO SYSTEMS INC 170 WEST TASMAN DR SAN JOSE CA 95134 9916 ...

Страница 3: ...70 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 526 4100 Catalyst 3750 Switch Hardware Installation Guide February 2004 Customer Order Number DOC 7815136 Text Part Number 78 15136 03 ...

Страница 4: ...difying the equipment without Cisco s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital devices In that event your right to use the equipment may be limited by FCC regulations and you may be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment ...

Страница 5: ...rChannel EtherFast EtherSwitch Fast Step GigaDrive GigaStack HomeLink Internet Quotient IOS IP TV iQ Expertise the iQ logo iQ Net Readiness Scorecard LightStream Linksys MeetingPlace MGX the Networkers logo Networking Academy Network Registrar Packet PIX Post Routing Pre Routing ProConnect RateMUX Registrar ScriptShare SlideCast SMARTnet StrataView Plus SwitchProbe TeleRouter The Fastest Way to In...

Страница 6: ......

Страница 7: ... Ordering Documentation xxv Documentation Feedback xxvi Obtaining Technical Assistance xxvi Cisco TAC Website xxvi Opening a TAC Case xxvii TAC Case Priority Definitions xxvii Obtaining Additional Publications and Information xxviii C H A P T E R 1 Using Express Setup 1 1 Taking Out What You Need 1 3 Powering On the Switch 1 4 Starting Express Setup 1 5 Configuring the Switch 1 11 Rerunning Expres...

Страница 8: ...atures 2 1 Front Panel Description 2 4 10 100 Ports 2 8 10 100 1000 Ports 2 11 SFP Module Slots 2 12 SFP Modules 2 12 XENPAK Module Slot 2 13 LEDs 2 13 System LED 2 16 RPS LED 2 16 Master LED 2 17 Port LEDs and Modes 2 17 Rear Panel Description 2 23 StackWise Ports 2 25 Power Connectors 2 25 Internal Power Supply Connector 2 25 Cisco RPS Connector 2 26 Console Port 2 27 Management Options 2 28 Net...

Страница 9: ...3 10 Connecting a PC or Terminal to the Console Port 3 10 Powering On the Switch and Running POST 3 12 Powering Off the Switch and Disconnecting the Console Port 3 13 Planning the Stack 3 14 Planning Considerations 3 14 Powering Considerations 3 15 Cabling Considerations 3 15 Recommended Cabling Configurations 3 17 Installing the Switch 3 19 Rack Mounting 3 19 Removing Screws from the Switch 3 20 ...

Страница 10: ...P Module Slots 3 42 Removing SFP Modules from SFP Module Slots 3 44 Installing and Removing XENPAK Modules 3 45 Installing a XENPAK Module 3 46 Removing a XENPAK Module 3 49 Connecting to the 10 100 and 10 100 1000 Ports 3 51 Connecting to an SFP Module 3 55 Connecting to a Fiber Optic SFP Module 3 56 Connecting to 1000BASE T SFP Modules 3 58 Connecting to a XENPAK Module 3 59 Where to Go Next 3 6...

Страница 11: ... 6 Four Twisted Pair Cable Pinouts for 1000BASE T Ports B 7 Crossover Cable and Adapter Pinouts B 8 Identifying a Crossover Cable B 8 Adapter Pinouts B 9 A P P E N D I X C Configuring the Switch with the CLI Based Setup Program C 1 Accessing the CLI C 2 Accessing the CLI Through Express Setup C 2 Accessing the CLI Through the Console Port C 3 Taking Out What You Need C 4 Stacking the Switches Opti...

Страница 12: ...moval Warning D 10 Stacking the Chassis Warning D 12 Main Disconnecting Device D 14 Grounded Equipment Warning D 15 Installing or Replacing the Unit D 16 Overtemperature Warning D 18 Working During Lightning Activity D 20 Product Disposal Warning D 21 Chassis Warning for Rack Mounting and Servicing D 23 Redundant Power Supply Connection Warning D 27 Switch Installation Warning D 29 Restricted Area...

Страница 13: ...warranty and license agreements from Cisco com 1 Launch your browser and go to this URL http www cisco com univercd cc td doc es_inpck cetrans htm The Warranties and License Agreements page appears 2 To read the Cisco Information Packet follow these steps a Click the Information Packet Number field and make sure that the part number 78 5235 03A0 is highlighted b Select the language in which you wo...

Страница 14: ...cument in Adobe Portable Document Format PDF You can also contact the Cisco service and support website for assistance http www cisco com public Support_root shtml Duration of Hardware Warranty Ninety 90 days Replacement Repair or Refund Policy for Hardware Cisco or its service center will use commercially reasonable efforts to ship a replacement part within ten 10 working days after receipt of a ...

Страница 15: ...n Guide 78 15136 03 Cisco 90 Day Limited Hardware Warranty Terms Complete the information below and keep it for reference Company product purchased from Company telephone number Product model number Product serial number Maintenance contract number ...

Страница 16: ...Cisco 90 Day Limited Hardware Warranty Terms xiv Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 17: ... It describes the physical and performance characteristics of each switch explains how to install a switch and provides troubleshooting information This guide does not describe system messages that you might receive or how to configure your switch For more information refer to the switch software configuration guide the switch command reference and the switch system message guide on the Cisco com ...

Страница 18: ...ed with electrical circuitry and be familiar with standard practices for preventing accidents Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device SAVE THESE INSTRUCTIONS Waarschuwing BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar U verkeert in een situatie die lichamelijk ...

Страница 19: ...ravailler sur un équipement soyez conscient des dangers liés aux circuits électriques et familiarisez vous avec les procédures couramment utilisées pour éviter les accidents Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil référez vous au numéro de l instruction situé à la fin de chaque avertissement CONSER...

Страница 20: ...jon som kan føre til skade på person Før du begynner å arbeide med noe av utstyret må du være oppmerksom på farene forbundet med elektriske kretser og kjenne til standardprosedyrer for å forhindre ulykker Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten TA VARE PÅ DISSE INSTRUKSJONENE Aviso INSTRUÇÕES IMPORTANTES DE...

Страница 21: ...rará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES Varning VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara Du befinner dig i en situation som kan leda till personskada Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga f...

Страница 22: ...Preface Conventions xx Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 23: ...xxi Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Preface Conventions ...

Страница 24: ...Preface Conventions xxii Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 25: ...xxiii Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Preface Conventions ...

Страница 26: ...pgrading the switch refer to the release notes on Cisco com for the latest information Catalyst 3750 Switch Software Configuration Guide order number DOC 7815164 Catalyst 3750 Switch Command Reference order number DOC 7815165 Catalyst 3750 Switch System Message Guide order number DOC 7815166 Cluster Management Suite CMS online help available only from the switch CMS software Catalyst 3750 Switch H...

Страница 27: ...site at this URL http www cisco com International Cisco websites can be accessed from this URL http www cisco com public countries_languages shtml Ordering Documentation You can find instructions for ordering documentation at this URL http www cisco com univercd cc td doc es_inpck pdi htm You can order Cisco documentation in these ways Registered Cisco com users Cisco direct customers can order Ci...

Страница 28: ...stance Center TAC provides 24 hour a day award winning technical support services online and over the phone Cisco com features the Cisco TAC website as an online starting point for technical assistance If you do not hold a valid Cisco service contract please contact your reseller Cisco TAC Website The Cisco TAC website provides online documents and tools for troubleshooting and resolving technical...

Страница 29: ...running smoothly To open a case by telephone use one of the following numbers Asia Pacific 61 2 8446 7411 Australia 1 800 805 227 EMEA 32 2 704 55 55 USA 1 800 553 2447 For a complete listing of Cisco TAC contacts go to this URL http www cisco com warp public 687 Directory DirTAC shtml TAC Case Priority Definitions To ensure that all cases are reported in a standard format Cisco has established ca...

Страница 30: ...ttp cisco com univercd cc td doc pcat Cisco Press publishes a wide range of general networking training and certification titles Both new and experienced users will benefit from these publications For current Cisco Press titles and other information go to Cisco Press online at this URL http www ciscopress com Packet magazine is the Cisco quarterly publication that provides the latest networking tr...

Страница 31: ...hed by Cisco Systems for engineering professionals involved in designing developing and operating public and private internets and intranets You can access the Internet Protocol Journal at this URL http www cisco com ipj Training Cisco offers world class networking training Current offerings in network training are listed at this URL http www cisco com en US learning index html ...

Страница 32: ...Preface Obtaining Additional Publications and Information xxx Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 33: ...up is supported on switches running Cisco IOS Release 12 1 14 EA1 or later When you are installing a switch refer to the Cisco IOS release label on the rear panel of the switch to determine the software release For setup instructions using the CLI based setup program go to Appendix C Configuring the Switch with the CLI Based Setup Program Note Before connecting the switch to a power source review ...

Страница 34: ...ss Setup is started should receive an address from the switch If your PC has a statically assigned IP address you should change your PC to use DHCP temporarily to complete the Express Setup procedure You need this information from your system administrator before you complete the setup program Fixed IP address Subnet mask IP netmask Default gateway IP address You can also configure these optional ...

Страница 35: ...the shipping container Figure 1 1 Catalyst 3750 Switch and AC Power Cord You also need to provide an Ethernet Category 5 straight through cable not included as shown in Figure 1 2 to connect the switch to your PC or workstation Figure 1 2 Ethernet Cable 1 Switch 2 AC power cord 1 2 97175 Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 89887 ...

Страница 36: ... panel as shown in Figure 1 3 Figure 1 3 Connecting the Power Step 2 Connect the other end of the power cable to a grounded AC outlet As the switch powers on it begins the power on self test POST a series of tests that runs automatically to ensure that the switch functions properly POST lasts approximately 1 minute 1 Switch 2 AC power cord 97176 1 2 RATING 100 240V 1 2A 0 6A 50 60 HZ DC INPUTS FOR...

Страница 37: ...T fails see Chapter 4 Troubleshooting to determine a course of action Starting Express Setup Express Setup provides the minimum configuration for a switch You do not create a username with Express Setup To create a username for the switch use the Cluster Management Suite CMS or the command line interface CLI Note Before starting Express Setup verify that the switch has passed POST and that the SYS...

Страница 38: ...are connected to the switch Step 2 Press and hold the Mode button as shown in Figure 1 4 until the four LEDs above the Mode button turn green This takes approximately 2 seconds Note On the Catalyst 3750 24PS and 3750 48PS switches the five LEDs above the Mode button turn green during this step Figure 1 4 Catalyst 3750 switch Mode Button 1 Mode button SYST RPS MASTR STAT DUPLX SPEED STACK MODE 9717...

Страница 39: ...LEDs mean that the switch has already been configured and cannot go into Express Setup mode For more information see the Clearing the Switch IP Address and Configuration section on page 4 2 Step 4 Connect a straight through Ethernet cable not included to an Ethernet port on the front panel of the switch as shown in Figure 1 6 Caution Do not connect the switch to any device other than the PC or wor...

Страница 40: ...t status LEDs on both connected Ethernet ports are green Step 6 Wait approximately 30 seconds after the port LEDs turn green and launch a web browser on your PC or workstation Step 7 Enter the IP address 10 0 0 1 as shown in Figure 1 7 and press Enter Figure 1 7 Entering the IP Address The Express Setup home page appears as shown in Figure 1 8 1 Switch 3 PC or workstation 2 Ethernet cable Catalyst...

Страница 41: ...ng the IP address in your browser If not wait 30 seconds and re enter 10 0 0 1 in the browser and press Enter Did you enter the wrong address in the browser or is there an error message displayed in the browser window Re enter 10 0 0 1 in the browser and press Enter Did you connect a crossover instead of a straight through Ethernet cable between an Ethernet port of the switch and the Ethernet port...

Страница 42: ...the type of device on the other end of the connection The Auto MDIX feature is enabled by default on switches running Cisco IOS Release 12 2 18 SE or later If not reconnect the straight through cable to the Ethernet port on the switch and PC or workstation Wait 30 seconds before entering 10 0 0 1 in the browser Did you verify that POST successfully ran before starting Express Setup If not make sur...

Страница 43: ...and select an IP Subnet Mask Step 5 Enter the IP address for the default gateway in the Default Gateway field A gateway router or dedicated network device is a system that connects a network on one subnet to one or more networks on a different subnet You must specify a default gateway if the management workstation and the switch are on different IP segments Step 6 Enter your password in the Switch...

Страница 44: ...in the Confirm Telnet Password field Step 12 Optional Click Enable to configure Simple Network Management Protocol SNMP Enable SNMP only if you plan to manage switches by using Cisco Works or another SNMP based network management system If you enable SNMP you must enter a community string in the SNMP Read Community field the SNMP Write Community field or both SNMP community strings authenticate ac...

Страница 45: ...e the IP address of your switch you can clear the IP address on your switch by following the steps in the Clearing the Switch IP Address and Configuration section on page 4 2 Verifying Switch IP Address This procedure is optional After you have installed the switch in your network follow these steps to verify the IP address configured on your switch Step 1 Launch a web browser on a PC or workstati...

Страница 46: ...Next 1 14 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Figure 1 9 Switch Home Page Where to Go Next After you have saved your configuration to the switch you can install the switch or further configure it by using CMS or the CLI ...

Страница 47: ... switch or switch clusters display network topologies to gather link information and display switch images to modify switch and port level settings For more information refer to the switch software configuration guide Tools Access diagnostic and monitoring tools such as Telnet and Extended Ping Help Resources Access Catalyst 3750 documentation Installing or Connecting Devices to the Switch For det...

Страница 48: ...Chapter 1 Using Express Setup Where to Go Next 1 16 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 49: ...h as servers routers and other switches This chapter provides a functional overview of the Catalyst 3750 switch models These topics are included Features page 2 1 Front Panel Description page 2 4 Rear Panel Description page 2 23 Management Options page 2 28 Features The switches can be deployed as backbone switches aggregating 10BASE T 100BASE TX and 1000BASE T Ethernet traffic from other network ...

Страница 50: ...Catalyst 3750G 12S 12 SFP module slots Catalyst 3750 24PS switch 24 10 100 Power over Ethernet PoE ports and 2 SFP module slots Catalyst 3750 48PS switch 48 10 100 PoE ports and 4 SFP module slots Catalyst 3750G 16TD switch 16 10 100 1000 Ethernet ports and 1 10 Gigabit Ethernet XENPAK module slot Note The 10 Gigabit Ethernet XENPAK modules are referred to as 10 Gigabit Ethernet module ports in th...

Страница 51: ...You can stack up to nine switches in a stack by cabling the StackWise ports StackWise ports are not user configurable Switches are hot swappable Power redundancy Connection for optional Cisco RPS 300 redundant power system that operates on AC input and supplies backup DC power output to the Catalyst 3750 24TS 3750G 24T 3750 48TS and 3750G 12S switches Note The Cisco RPS 300 does not support the Ca...

Страница 52: ...dule slots are numbered 1 left and 2 right Figure 2 1 Catalyst 3750 24TS Front Panel The 10 100 1000 ports on the Catalyst 3750G 24T and 3750G 24TS are grouped in pairs The first member of the pair port 1 is above the second member port 2 as shown in Figure 2 2 and Figure 2 3 Port 3 is above port 4 and so on In Figure 2 3 the SFP module slots are numbered 25 to 28 1 10 100 ports 2 SFP module slots...

Страница 53: ...2 The slots are grouped in three sets of four as shown in Figure 2 4 1 10 100 1000 ports 1 10 100 ports 2 SFP module slots Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 86543 Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 ...

Страница 54: ...t 3 is above port 4 and so on The SFP module slots are numbered 1 top and 2 bottom and so on Figure 2 5 Catalyst 3750 48TS Front Panel 1 SFP module slots Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 4 1 2 3 12 9 10 11 8 5 6 7 1 97166 1 10 100 ports 2 SFP module slots Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X 2X 17X 18X 33X 34X 15X 16X 31X 32X 47X 48X 1 3...

Страница 55: ...ber of the pair port 1 is above the second member port 2 as shown in Figure 2 7 Port 3 is above port 4 and so on The SFP module slots are numbered 1 to 4 Figure 2 7 Catalyst 3750 48PS Switch Front Panel 1 10 100 PoE ports 2 SFP module slots 104577 2 Catalyst 3560 SERIES SYST RPS STAT DUPLX SPEED PoE MODE 1 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 13 1 2 1X 2X 11X 12X 13X 14X 23X...

Страница 56: ...mbination of half duplex full duplex 10 Mbps or 100 Mbps You can also set these ports for speed and duplex autonegotiation in compliance with IEEE 802 3ab The default setting is autonegotiate When set for autonegotiation the port senses the speed and duplex settings of the attached device and advertises its own capabilities If the connected device also supports autonegotiation the switch port nego...

Страница 57: ...ote You can use the mdix auto interface configuration command in the CLI to enable the automatic medium dependent interface crossover Auto MDIX feature When the Auto MDIX feature is enabled the switch detects the required cable type for copper Ethernet connections and configures the interfaces accordingly Therefore you can use either a crossover or a straight through cable for connections to a cop...

Страница 58: ... can deliver an average of 7 7 W of PoE at the same time up to a maximum switch power output of 370 W On a per port basis you can control whether or not a 10 100 port on a Catalyst 3750 24PS or Catalyst 3750 48PS switch automatically provides power when an IP phone or an access point is connected CMS and the CLI provide two PoE settings for each 10 100 port Auto and Never When you select the Auto ...

Страница 59: ...tiation the switch port negotiates the best connection that is the fastest line speed that both devices support and full duplex transmission if the attached device supports it and configures itself accordingly In all cases the attached device must be within 328 feet 100 meters Note You can configure duplex mode to half full or autonegotiate on Gigabit Ethernet interfaces if the speed is set to 10 ...

Страница 60: ...ature is enabled by default on switches running Cisco IOS Release 12 2 18 SE or later For releases between Cisco IOS Release 12 1 14 EA1 and 12 2 18 SE the Auto MDIX feature is disabled by default For configuration information for this feature refer to the switch software configuration guide or the switch command reference SFP Module Slots Catalyst 3750 switches with SFP module slots support these...

Страница 61: ...nt panel For a list of the XENPAK modules that the Catalyst 3750G 16TD switch supports refer to the Catalyst 3750 release notes For more information about XENPAK modules refer to your XENPAK module documentation Note The 10 Gigabit Ethernet XENPAK modules are referred to as 10 Gigabit Ethernet module ports in the software documentation LEDs You can use the switch LEDs to monitor switch activity an...

Страница 62: ...6 03 Figure 2 9 Catalyst 3750 24TS 3750G 24T 3750G 12S 3750G 16TD 3750 48TS and 3750G 24TS LEDs 1 Mode button 6 Master LED 2 Stack LED 7 RPS LED 3 Speed LED 8 System LED 4 Duplex LED 9 Port LED 5 Status LED SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 86545 2 3 4 5 6 7 8 1 9 ...

Страница 63: ... 2 Product Overview Front Panel Description Figure 2 10 Catalyst 3750 24PS and 3750 48PS LEDs 1 Mode button 6 Status LED 2 PoE LED 7 Master LED 3 Stack LED 8 RPS LED 4 Speed LED 9 System LED 5 Duplex LED RPS SYST MASTR STAT DUPLX SPEED STACK PoE MODE 2 3 4 5 7 8 1 6 9 104062 ...

Страница 64: ...owered on Green System is operating normally Amber System is receiving power but is not functioning properly Table 2 2 RPS LED Color RPS Status Off RPS is off or not properly connected Green RPS is connected and ready to provide back up power if required Flashing green RPS is connected but is unavailable because it is providing power to another device redundancy has been allocated to a neighboring...

Страница 65: ...bout the individual ports The port modes determine the type of information displayed through the port LEDs Table 2 4 lists the mode LEDs and their associated port mode and meaning To select or change a mode press the Mode button until the desired mode is highlighted When you change port modes the meanings of the port LED colors also change Table 2 6 explains how to interpret the port LED colors in...

Страница 66: ...perate only in full duplex mode SPEED Port speed The port operating speed 10 100 or 1000 Mbps STACK Stack member status StackWise port status The stack member status The StackWise port status See the Stack LED section on page 2 21 for more information PoE1 1 The PoE LED is only on the Catalyst 3750 24PS and 3750 48PS switches 10 100 PoE port power The PoE status Table 2 5 PoE Mode LED Color PoE St...

Страница 67: ...y when the switch port is providing power Alternating green and amber PoE is denied because providing power to the powered device will exceed the 370 W switch power capacity Blinking amber PoE is off due to a fault Caution PoE faults are caused when noncompliant cabling or powered devices are connected to a PoE port Only standard compliant cabling can be used to connect Cisco pre standard IP Phone...

Страница 68: ...ecks the switch for possible loops Flashing amber Port is blocked by STP and is transmitting or receiving packets DUPLX duplex Off Port is operating in half duplex Green Port is operating in full duplex SPEED 10 100 and 10 100 1000 ports Off Port is operating at 10 Mbps Green Port is operating at 100 Mbps Flashing green Port is operating at 1000 Mbps SFP ports Off Port is operating at 10 Mbps Gree...

Страница 69: ...ckWise ports on the switch rear panel are up and the representative stack LEDs are amber when the ports are down SFP port LEDs 1 and 2 on the Catalyst 3750 24TS switch show the status for StackWise ports 1 and 2 respectively SFP port LEDs 3 and 4 on the Catalyst 3750 48TS switch show the status for StackWise ports 1 and 2 respectively SFP port LEDs 27 and 28 on the Catalyst 3750G 24TS switch show ...

Страница 70: ...48X 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 15 16 Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X 2X 17X 18X 33X 34X 15X 16X 31X 32X 47X 48X 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 15 16 ...

Страница 71: ...ector an RJ 45 console port and two StackWise ports See Figure 2 12 through Figure 2 13 Figure 2 12 Catalyst 3750 24TS 3750G 24T 3750G 12S 3750G 16TD and 3750 48TS Rear Panel 1 StackWise ports 4 AC power connector 2 RJ 45 console port 5 RPS connector 3 Fan exhaust RATING 100 200V 1 6A 0 9A 50 60 HZ DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 8 5a CONSOLE STACK 1 STACK 2 1 2 3 4 5 865...

Страница 72: ... StackWise ports 4 AC power connector 2 RJ 45 console port 5 RPS connector 3 Fan exhaust 1 StackWise ports 4 AC power connector 2 RJ 45 console port 5 RPS connector 3 Fan exhaust CONSOLE STACK 1 STACK 2 DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 17a 1 2 3 4 5 86547 104763 RATING 100 240V 1 6A 0 9A 50 60 HZ DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 8 5A CONSOLE STACK ...

Страница 73: ...r these StackWise cables from your Cisco sales representative CAB STACK 50CM 0 5 meter cable CAB STACK 1M 1 meter cable CAB STACK 3M 3 meter cable Power Connectors The switch is powered through the internal power supply You can also connect the Cisco RPS 300 or the Cisco RPS 675 to provide backup power if the switch internal power supply should fail Note The Catalyst 3750 switch and the Cisco RPS ...

Страница 74: ... 3750G 12S and 3750 48TS switches Cisco RPS 675 model PWR675 AC RPS N1 supports the Catalyst 3750 family of switches Cisco RPS 300 The Cisco RPS 300 has two output levels 48V and 12V with a total maximum output power of 300W Use the supplied RPS connector cable to connect the RPS to the switch Note The Cisco RPS 300 does not support the Catalyst 3750G 24TS 3750 24PS 3750 48PS and 3750G 16TD switch...

Страница 75: ...g Attach only the Cisco RPS model PWR675 AC RPS N1 to the RPS receptacle The RPS is a redundant power system that can support six external network devices and provides power to one failed device at a time It automatically senses when the internal power supply of a connected device fails and provides power to the failed device preventing loss of network traffic For more information on the Cisco RPS...

Страница 76: ... configure and monitor the switch and switch cluster members from the CLI You can access the CLI either by connecting your management station directly to the switch console port or by using Telnet from a remote management station Refer to the Catalyst 3750 Switch Command Reference on Cisco com for more information CiscoView application The CiscoView device management application displays the switc...

Страница 77: ...verview Management Options Network Configurations Refer to the switch software configuration guide on Cisco com for network configuration concepts and examples of using the switch to create dedicated network segments and interconnecting the segments through Gigabit Ethernet connections ...

Страница 78: ...Chapter 2 Product Overview Management Options 2 30 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 79: ...l the switch and make connections to the switch Read the topics and perform the procedures in this order Preparing for Installation page 3 2 Verifying Switch Operation page 3 10 Planning the Stack page 3 14 Installing the Switch page 3 19 Connecting StackWise Cable to StackWise Ports page 3 38 Installing and Removing SFP Modules page 3 41 Installing and Removing XENPAK Modules page 3 45 Connecting...

Страница 80: ...made using uninsulated exposed metal contacts conductors or terminals Avoid using such interconnection methods unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard A restricted access area can be accessed only through the use of a special tool lock and key or...

Страница 81: ...e at all times because it serves as the main disconnecting device Warning To prevent the switch from overheating do not operate it in an area that exceeds the maximum recommended ambient temperature of 113 F 45 C To prevent airflow restriction allow at least 3 inches 7 6 cm of clearance around the ventilation openings Warning When installing or replacing the unit the ground connection must always ...

Страница 82: ...id direct exposure to the laser beam EMC Regulatory Statements This section includes specific regulatory statements about the Catalyst 3750 family of switches U S A U S regulatory information for this product is in the front matter of this manual Class A Notice for Taiwan and Other Traditional Chinese Markets Warning This is a Class A Information Product when used in residential environment it may...

Страница 83: ...ol Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Warning This is a Class A Device and is registered for EMC requirements for industrial use The seller or buyer should be aware of this If this type was sold or purchased by m...

Страница 84: ... Class A Notice for Hungary Warning This equipment is a class A product and should be used and installed properly according to the Hungarian EMC Class A requirements MSZEN55022 Class A equipment is designed for typical commercial establishments for which special conditions of installation and protection distance are used ...

Страница 85: ... ZX and CWDM fiber optic SFP module connections Each port must match the wave length specifications on the other end of the cable and for reliable communications the cable must not exceed the stipulated cable length Table 3 1 Fiber Optic SFP Module Port Cabling Specifications SFP Module Wavelength nanometers Fiber Type Core Size micron Modal Bandwidth MHz km Cable Distance 1000BASE SX 850 MMF 62 5...

Страница 86: ...0 1570 1590 1610 SMF 9 125 62 miles 100 km 1 A mode conditioning patch cord is required Using an ordinary patch cord with MMF 1000BASE LX LH SFP modules and a short link distance can cause transceiver saturation resulting in an elevated bit error rate BER When using the LX LH SFP module with 62 5 micron diameter MMF you must also install a mode conditioning patch cord between the SFP module and th...

Страница 87: ...he shipping container and check each item for damage If any item is missing or damaged contact your Cisco representative or reseller for support Return all packing material to the shipping container and save it The switch is shipped with these items This Catalyst 3750 Switch Hardware Installation Guide About the Catalyst 3750 Documentation flyer AC power cord AC powered switches One RJ 45 to DB 9 ...

Страница 88: ...and verify that the switch passes POST These sections describe the steps required to connect a PC to the switch console port and to power on the switch and observe POST Connecting a PC or Terminal to the Console Port page 3 10 Powering On the Switch and Running POST page 3 12 Connecting a PC or Terminal to the Console Port To connect a PC to the console port use the supplied RJ 45 to DB 9 adapter ...

Страница 89: ...op bit No parity None flow control After you have gained access to the switch you can change the console baud rate through the Administration Console Baud Rate window in the Cluster Management Suite CMS Step 2 Using the supplied RJ 45 to DB 9 adapter cable insert the RJ 45 connector into the console port as shown in Figure 3 1 Step 3 Attach the DB 9 female DTE adapter of the RJ 45 to DB 9 adapter ...

Страница 90: ... information Note Always put the RPS in standby mode when you are connecting devices to it and in active mode during normal operation To power on the switch follow these steps Step 1 Make sure that you have started the terminal emulation software program such as ProComm HyperTerminal tip or minicom from your management station See the Connecting a PC or Terminal to the Console Port section on page...

Страница 91: ...at the switch functions properly POST lasts approximately 1 minute When the switch begins POST the System the RPS the Master the Status the Duplex the Speed and the Stack LEDs turn green On the Catalyst 3750 24PS and 3750 48PS switches the PoE LED also turns green as POST begins The System LED flashes green and the other LEDs remain continuous green When POST completes successfully the System LED ...

Страница 92: ...n the other switches Stacking together switches of the same size will make it easier to cable the switches Length of cable Depending on the configurations you have you might need different sized cables If you don t specify the length of the StackWise cable the 0 5 meter cable is supplied If you require the 1 meter cable or 3 meter cable you can order it from your Cisco supplier For cable numbers s...

Страница 93: ... master power on the all the switches in the stack within a 10 second timeframe These switches participate in the stack master election Switches powered on after the 10 second timeframe do not participate in the election Power off a switch before you add it to or remove it from an existing switch stack Note For conditions that can cause a stack master re election or to manually elect the stack mas...

Страница 94: ...alf Bandwidth Connections Figure 3 4 and Figure 3 5 show examples of stacks of Catalyst 3750 switches with failover conditions In Figure 3 4 the StackWise cable is bad in link B therefore this stack provides only half bandwidth and does not have redundant connections In Figure 3 5 link B is bad therefore this stack partitions into two stacks and switch 1 and switch 3 are stack masters Figure 3 4 E...

Страница 95: ...s an example of a recommended configuration using the supplied 0 5 meter StackWise cable In this example the switches are stacked in a vertical rack or on a table This configuration provides redundant connections Figure 3 6 Stacking the Switches in a Vertical Rack or on a Table Using the 0 5 meter StackWise Cable The configuration examples in Figure 3 7 use the 3 meter StackWise cable in addition ...

Страница 96: ...e Mounting in a Rack or on a Wall Figure 3 8 and Figure 3 9 are examples of recommended configurations where the switches are rack or wall mounted side by side Use the 1 meter and 3 meter StackWise cables to connect the switches These configuration provide redundant connections Figure 3 8 Stacking up to Eight Switches in a Side by Side Mounting Configuration Figure 3 9 Stacking Nine Switches in a ...

Страница 97: ...kets to the Catalyst 3750 24TS 3750G 24T 3750G 12S 3750 24PS 3750 48PS 3750G 16TD and 3750 48TS Switches page 3 26 Mounting the Switch in a Rack page 3 29 Attaching the Cable Guide page 3 31 Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your s...

Страница 98: ...er RCKMNT 3550 1 5RU For the Catalyst 3750 24TS 3750G 24T 3750G 12S and 3750 48TS switches order part number RCKMNT 1RU Removing Screws from the Switch If you plan to install the switch in a rack you must first remove screws in the switch chassis so that mounting brackets can be attached Figure 3 10 and Figure 3 11 show how to remove the chassis screws in a one rack unit RU switch Figure 3 10 Remo...

Страница 99: ... to the Catalyst 3750G 24TS Switch The bracket orientation and the brackets that you use depend on whether you are attaching the brackets for a 19 inch or a 24 inch rack For 19 inch racks use part number 700 11523 XX for 24 inch racks use part number 700 12398 XX Figure 3 13 through Figure 3 18 show how to attach each type bracket to one side of the switch Follow the same steps to attach the secon...

Страница 100: ...t 3750 Switch Hardware Installation Guide 78 15136 03 Figure 3 13 Attaching Brackets for 19 inch Racks Front Panel Forward 1 Phillips flat head screws SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 86839 ...

Страница 101: ...e 78 15136 03 Chapter 3 Switch Installation Installing the Switch Figure 3 14 Attaching Brackets for 24 Inch Racks Front Panel Forward 1 Phillips flat head screws SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 86557 1 ...

Страница 102: ... 3 15 Attaching Brackets for 19 Inch Racks Rear Panel Forward Figure 3 16 Attaching Brackets for 24 Inch Racks Rear Panel Forward 1 Phillips flat head screws 1 Phillips flat head screws DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 17a 86555 1 DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 17a 86556 1 ...

Страница 103: ...ching Brackets for 19 Inch Telco Racks Figure 3 18 Attaching Brackets for 24 Inch Telco Racks 1 Phillips flat head screws 1 Phillips flat head screws Catalyst 3750 SERIES 13X 14X 23X 24X 25 26 27 28 13 14 15 16 17 18 19 20 21 22 23 24 86558 1 Catalyst 3750 SERIES 13X 14X 23X 24X 25 26 27 28 13 14 15 16 17 18 19 20 21 22 23 24 86559 1 ...

Страница 104: ...aching the brackets for a 19 inch or a 24 inch rack For 19 inch racks use bracket part number 700 8209 XX for 24 inch racks use bracket part number 700 13248 XX Figure 3 19 through Figure 3 25 show how to attach each type bracket to one side of the switch Follow the same steps to attach the second bracket to the opposite side Figure 3 19 Attaching Brackets for 19 Inch Racks Front Panel Forward 1 P...

Страница 105: ...rackets for 24 Inch Racks Front Panel Forward Figure 3 21 Attaching Brackets for 19 Inch Racks Rear Panel Forward 1 Phillips flat head screws 1 Phillips flat head screws SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X 2X 1 2 3 4 5 86561 1 RATING 100 200V 1 6A 0 9A 50 60 HZ DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 8 5a 1 86562 ...

Страница 106: ... 24 Inch Racks Rear Panel Forward Figure 3 23 Attaching Brackets for 19 Inch Telco Racks 1 Phillips flat head screws 1 Phillips flat head screws RATING 100 200V 1 6A 0 9A 50 60 HZ DC INPUTS FOR REMOTE POWER SUPPLY SPECIFIED IN MANUAL 12v 8 5a 1 86563 Catalyst 3750 SERIES 13X 14X 23X 24X 11X 12X 1 2 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 86564 ...

Страница 107: ... Mounting the Switch in a Rack After the brackets are attached to the switch use the four supplied number 12 Phillips machine screws to securely attach the brackets to the rack as shown in Figure 3 26 and Figure 3 27 1 Phillips truss head screws 1 Phillips flat head screws Catalyst 3750 SERIES 16 8 12 9 10 11 97171 1 Catalyst 3750 SERIES 13X 14X 23X 24X 11X 12X 1 2 9 10 11 12 13 14 15 16 17 18 19 ...

Страница 108: ...Phillips machine screws Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 86566 1 Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 86567 1 Catalyst 3750 SERIES SYST RPS ...

Страница 109: ...tions section on page 3 15 Run the setup program See the Completing the Setup Program section on page C 11 Connect to the front panel ports See the Connecting to the 10 100 and 10 100 1000 Ports section on page 3 51 the Connecting to an SFP Module section on page 3 55 and the Connecting to a XENPAK Module section on page 3 59 to complete the installation To use the CLI enter commands at the Switch...

Страница 110: ...plied black screw to mount it on the left bracket Figure 3 29 Attaching the Cable Guide on the Catalyst 3750 48TS Switch 1 Cable guide screws 1 Cable guide screws Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 86568 Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 1X...

Страница 111: ...h on a Wall page 3 35 Note The illustrations in this section show the Catalyst 3750G 24TS switch as an example All the Catalyst 3750 switches are wall mounted following the same procedures Attaching the Brackets to the Switch for Wall Mounting Figure 3 30 shows how to attach a 19 inch bracket to one side of the switch Follow the same steps to attach the second bracket to the opposite side Figure 3...

Страница 112: ...ch the RPS connector cover to the back of the switch as shown in Figure 3 31 and Figure 3 32 Warning If an RPS is not connected to the switch install an RPS connector cover on the back of the switch Figure 3 31 Attaching the RPS Connector Cover on the Catalyst 3750G 24TS Switch 1 Phillips pan head screws 3 RPS connector 2 RPS connector cover CONSOLE STACK 1 STACK 2 DC INPUTS FOR REMOTE POWER SUPPL...

Страница 113: ...pport of the switch and cables make sure the switch is attached securely to wall studs or to a firmly attached plywood mounting backboard Mount the switch with the front panel facing up as shown in Figure 3 33 Warning To comply with safety regulations mount the switches on a wall with the front panel facing up 1 Phillips pan head screws 3 RPS connector 2 RPS connector cover RATING 100 200V 1 6A 0 ...

Страница 114: ...e Ports section on page 3 38 Connect to the console port and start the emulation software See the Connecting to the Console Port section on page C 7 and the Starting the Terminal Emulation Software section on page C 9 Power on the switch See the Connecting to a Power Source section on page C 9 If the switches are stacked see the Powering Considerations section on page 3 15 1 User supplied screws C...

Страница 115: ... Mounting Follow these steps to install the switch on a table or shelf Step 1 Locate the adhesive strip with the rubber feet in the mounting kit envelope Attach the four rubber feet to the recessed areas on the bottom of the unit Step 2 Place the switch on the table or shelf near an AC power source After the switch is mounted on the table you might need to perform these tasks to complete the insta...

Страница 116: ...n refer to the switch software configuration guide or the switch command reference Connecting StackWise Cable to StackWise Ports Follow these steps to connect the StackWise cable to the StackWise ports Step 1 Remove the dust covers from the StackWise cables and StackWise ports and store them for future use Step 2 Insert one end of the StackWise cable into the StackWise port on the back of the swit...

Страница 117: ... to protect them from dust Figure 3 34 Inserting the StackWise Cable in a StackWise Port When you need to remove the StackWise cable from the connector make sure to fully unscrew the screws before removing the connector Also make sure that you remove the correct screws from the StackWise port See Figure 3 35 for correct removal procedures and Figure 3 36 for incorrect removal procedures CONSOLE ST...

Страница 118: ...allation Connecting StackWise Cable to StackWise Ports 3 40 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Figure 3 35 Correct Removal of the StackWise Cable from a StackWise Port CONSOLE STACK 1 STACK 2 86826 ...

Страница 119: ...of SFP modules Refer to the Catalyst 3750 release notes for the list of SFP modules that the Catalyst 3750 switch supports Each port must match the wave length specifications on the other end of the cable and the cable must not exceed the stipulated cable length for reliable communications See the Installation Guidelines section on page 3 7 for cable stipulations for SFP connections Use only Cisco...

Страница 120: ...ables attached because of the potential damage to the cables the cable connector or the optical interfaces in the SFP module Disconnect all cables before removing or installing an SFP module Removing and installing an SFP module can shorten its useful life Do not remove and insert SFP modules more often than is absolutely necessary Figure 3 37 SFP Module with a Bale Clasp Latch To insert an SFP mo...

Страница 121: ...le into the slot until you feel the connector on the module snap into place in the rear of the slot Figure 3 38 Installing an SFP Module into an SFP Module Slot Step 5 For fiber optic SFP modules remove the dust plugs from the optical ports and store them for later use Caution Do not remove the dust plugs from the fiber optic SFP module port or the rubber caps from the fiber optic cable until you ...

Страница 122: ... receptacle follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a bare metal surface on the chassis Step 2 Disconnect the cable from the SFP module Tip For reattachment note which cable connector plug is send TX and which is receive RX Step 3 For fiber optic SFP modules insert a dust plug into the optical ports of the SFP module to keep the optical interfaces clean ...

Страница 123: ... an antistatic bag or other protective environment Installing and Removing XENPAK Modules These sections describe how to install and remove XENPAK modules XENPAK modules are inserted into the XENPAK module slot on the front panel of the Catalyst 3750G 16TD switch These field replaceable transceiver modules provide 10 Gigabit interfaces Note The 10 Gigabit Ethernet XENPAK modules are referred to as...

Страница 124: ...ulations for XENPAK module connections For detailed instructions on installing removing cabling and troubleshooting the XENPAK module refer to your XENPAK module documentation Installing a XENPAK Module Figure 3 40 shows a XENPAK module Caution We strongly recommend that you do not install or remove fiber optic XENPAK modules with cables attached because of the potential damage to the cables the c...

Страница 125: ...hese steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a bare metal surface on the chassis Step 2 Remove the two Phillips head retaining screws from the XENPAK module slot cover and store them for later use Step 3 Remove the cover as shown in Figure 3 41 1 Captive installation screw 3 Transmit optical bore 2 Optical bore dust plug 4 Receive optical bore 2 99376 RX TX 1 3 4 ...

Страница 126: ...NPAK Module Slot Cover Step 4 Remove the XENPAK module from the protective packaging Step 5 Align the XENPAK module with the guide rails inside the module slot and slide the module into the opening until the back of the XENPAK faceplate is flush with the switch faceplate See Figure 3 42 1 Phillips head screw 2 Module slot cover Catalyst 3750 series 104764 2 1 1 ...

Страница 127: ...Module To remove a XENPAK module follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a bare metal surface on the chassis Step 2 Disconnect the cable from the XENPAK module For fiber optic modules install the optical bore dust plugs Step 3 Loosen the two captive installation screws that secure the XENPAK module in the slot Step 4 Carefully pull on the two captive ins...

Страница 128: ...the edges of the XENPAK module and carefully slide it out of the slot as shown in Figure 3 43 Figure 3 43 Removing a XENPAK Module Step 6 Use two Phillips head screws to attach the XENPAK module slot cover to the switch front panel as shown in Figure 3 44 1 Optical bore dust plug 2 Captive installation screw Catalyst 3750 series 104574 2 1 TX RX 1 ...

Страница 129: ...s If the attached ports do not support autonegotiation you can explicitly set the speed and duplex parameters Connecting devices that do not autonegotiate or that have their speed and duplex parameters manually set can reduce performance or result in no linkage To maximize performance choose one of these methods for configuring the Ethernet ports Let the ports autonegotiate both speed and duplex S...

Страница 130: ... 3750 24PS and 3750 48PS switches either to automatically provide PoE when a Cisco IP Phone Cisco Aironet Access Point or end device compliant with IEEE 802 3af is connected or never to provide PoE even if an IP phone or an access point is connected The default setting is Auto To prevent ESD damage follow your normal board and component handling procedures Use the guidelines in Table 3 2 to select...

Страница 131: ... EA1 and 12 2 18 SE the Auto MDIX feature is disabled by default For configuration information for this feature refer to the switch software configuration guide or the switch command reference Follow these steps to connect to 10BASE T 100BASE TX or 1000BASE T devices Caution PoE faults are caused when noncompliant cabling or powered devices are connected to a PoE port Only standard compliant cabli...

Страница 132: ...t fully support IEEE 802 3af might not support PoE when connected to the switches by a crossover cable Step 2 Connect the other end of the cable to an RJ 45 connector on the other device The port LED turns on when both the switch and the connected device have established link The port LED is amber while Spanning Tree Protocol STP discovers the topology and searches for loops This takes about 30 se...

Страница 133: ...s For instructions on how to connect to fiber optic SFP modules see the Connecting to 1000BASE T SFP Modules section For instructions on how to connect to 1000BASE T SFP modules see the Connecting to 1000BASE T SFP Modules section For instructions about how to install or remove an SFP module see the Installing and Removing SFP Modules section on page 3 41 SYST RPS MASTR STAT DUPLX SPEED STACK MODE...

Страница 134: ...ee Appendix B Connector and Cable Specifications for information about the LC on the SFP module Step 1 Remove the rubber plugs from the module port and fiber optic cable and store them for future use Step 2 Insert one end of the fiber optic cable into the SFP module port see Figure 3 46 Step 3 Insert the other cable end into a fiber optic receptacle on a target device Step 4 Observe the port statu...

Страница 135: ...3 46 Connecting to an SFP Module Port Step 5 If necessary reconfigure and restart the switch or target device Caution For detailed instructions on removing the SFP modules refer to your SFP documentation 1 LC connector 0 SERIES 23X 24X 1 2 86550 1 Catalyst 3750 SERIES 13X 14X 23X 24X 13 14 15 16 17 18 19 20 21 22 23 24 1 2 86550 1 ...

Страница 136: ...ert a four twisted pair straight through cable in the RJ 45 connector When connecting to switches or repeaters insert a four twisted pair crossover cable Note When connecting to a 1000BASE T device be sure to use a four twisted pair Category 5 cable Figure 3 47 Connecting to an SFP Module Port Step 2 Insert the other cable end in an RJ 45 connector on a target device Step 3 Observe the port status...

Страница 137: ...he rubber caps from the fiber optic cable until you are ready to connect the cable The plugs and caps protect the XENPAK module ports and cables from contamination and ambient light Note The 10 Gigabit Ethernet XENPAK modules are referred to as 10 Gigabit Ethernet module ports in the switch software documentation Note Make sure that the XENPAK module is fully inserted into the module slot and that...

Страница 138: ... turns amber while the STP discovers the network topology and searches for loops This process takes about 30 seconds and then the port LED turns green If the LED is off the target device might not be turned on there might be a cable problem or there might be problem with the adapter installed in the target device See Chapter 4 Troubleshooting for solutions to cabling problems Figure 3 48 Connectin...

Страница 139: ...o change the default configuration Start CMS as described in the switch software configuration guide and configure the switch as a member of a cluster or as an individual switch Use the CLI to configure the switch as a member of a cluster or as an individual switch from the console Refer to the Catalyst 3750 Switch Command Reference on Cisco com for information on using the CLI with a Catalyst 375...

Страница 140: ...Chapter 3 Switch Installation Where to Go Next 3 62 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 141: ...terface CLI or from a Simple Network Management Protocol SNMP workstation Refer to the software configuration guide the switch command reference guide on Cisco com or the documentation that came with your SNMP application for details This chapter describes these topics for troubleshooting problems Understanding POST Results page 4 1 Clearing the Switch IP Address and Configuration page 4 2 Replaci...

Страница 142: ...ails POST the System LED turns amber A POST failure usually means that there is physical damage to a port A common cause for failure is ESD If an Ethernet controller fails it results in port failure During the switch power up sequence you can monitor the POST tests through a console port connection When the switch is running you can also use the show post privileged EXEC command to see if any port...

Страница 143: ...inue holding down the Mode button The LEDs stop blinking after 8 additional seconds and then the switch reboots Note These steps only work on a previously configured switch The switch now behaves like an unconfigured switch You can configure the switch by using Express Setup as described in these sections Starting Express Setup section on page 1 5 Configuring the Switch section on page 1 11 Verify...

Страница 144: ...oftware configuration guide the switch command reference guide on Cisco com or the documentation that came with your SNMP application for details You can access the Technical Support Website http www cisco com techsupport for a list of known hardware problems and extensive troubleshooting documentation including Field notices Security advisories Troubleshooting resources Factory defaults Password ...

Страница 145: ...10 100 and 10 100 1000BASE T connections The distance between the port and the attached device exceeds 328 feet 100 meters If the switch is attached to a repeater the total distance between the two end stations exceeds the cabling guidelines SFP or XENPAK cabling guidelines exceeded Refer to the switch software configuration guide for information on displaying port statistics Reduce the cable leng...

Страница 146: ...per application of crossover vs straight through cables see the Two Twisted Pair Cable Pinouts section on page B 5 Enable the automatic medium dependent interface crossover Auto MDIX feature Note Many legacy powered devices including older Cisco IP phones and access points that do not fully support IEEE 802 3af might not support PoE when connected to the switches by a crossover cable Replace with ...

Страница 147: ...configuration command to verify the port status and enter a time interval to recover from the error disable state Refer to the switch command reference guide for information on the errdisable recovery command Powered device connected to PoE port but no power given Switch might not have enough power capacity to deliver PoE to a new powered device Use the Mode button to show the PoE status for all p...

Страница 148: ...onnect Cisco pre standard IP Phones and wireless access points or IEEE 802 3af compliant devices to PoE ports A cable or device that causes a PoE fault must be removed from the network Use the Mode button to show the PoE status for all ports The affected port LEDs blink amber or alternate green and amber If a port LED blinks amber there is a PoE fault A cable or device that causes a PoE fault must...

Страница 149: ...snap into the slot Verify that the SFP or XENPAK module is not installed upside down Remove the SFP or XENPAK module Inspect for physical damage to the connector the module and the module slot Replace the SFP or XENPAK module with a known good module No stack link between switches or high error rate between switches in the stack Poor cable connection Bad StackWise cable or damaged StackWise port S...

Страница 150: ...in the stack you need to manually assign the replacement switch the same member number as the failed switch To assign the member number manually refer to the switch software configuration guide Step 4 Make the same Ethernet and Gigabit Ethernet connections on the replacement switch as were on the failed switch Step 5 Power on the replacement switch The replacement switch will have the same configu...

Страница 151: ...the Catalyst 3750G 12S Switch Environmental Ranges Operating temperature 32 to 113 F 0 to 45 C Storage temperature 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 240 VAC autoranging 1 2A 0 6A 50 to 60 Hz DC input voltages for RPS 300 12V 13A DC input voltage...

Страница 152: ...ture 32 to 113 F 0 to 45 C Storage temperature 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 240 VAC autoranging 1 2A 0 6A 50 to 60 Hz DC input voltages for RPS 300 12V 8 5A DC input voltages for RPS 675 12V 8 5A Power consumption 50W 171 BTUs per hour Powe...

Страница 153: ...58 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 240 VAC autoranging 1 6A 0 9A 50 to 60 Hz DC input voltage for RPS 300 12V 13A DC input voltages for RPS 675 12V 13A Power consumption 165W 563 BTUs per hour Power rating 0 165 kVA Physical Dimensions Weight 10 lb 4 55...

Страница 154: ...condensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 127 200 to 240 VAC autoranging 5 5 A 2 8 A 50 to 60 Hz DC input voltage for RPS 675 12 V 7 5 A and 48 V 7 8 A Power consumption 495 W Power dissipation 125 W 426 BTUs per hour Power rating 0 495 kVA Power over Ethernet 15 4 W per port maximum 370 W switch maximum ...

Страница 155: ...perating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 127 200 to 240 VAC autoranging 5 5 A 2 8 A 50 to 60 Hz DC input voltages for RPS 675 12 V 7 5 A and 48 V 7 8 A Power consumption 540 W Power dissipation 170 W 580 BTUs per hour Power rating 0 54 kVA Power over Ethernet Range from 4 0 to 15 4 W per port up to 370 W switch maxi...

Страница 156: ...e 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 240 VAC autoranging 1 6A 0 9A 50 to 60 Hz DC input voltages for RPS 675 12V 17A Power consumption 180 W 615 BTUs per hour Power rating 0 180 kVA Physical Dimensions Weight 12 5 lb 5 68 kg Dimensions H x D x W ...

Страница 157: ...e 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitude Up to 15 000 ft 4573 m Power Requirements AC input voltage 100 to 240 VAC autoranging 2 3A 1 5A 50 to 60 Hz DC input voltages for RPS 675 12V 17A Power consumption 190W 650 BTUs per hour Power rating 0 190 kVA Physical Dimensions Weight 12 5 lb 5 68 kg Dimensions H x D x W 2...

Страница 158: ...C autoranging 1 2A 0 6A 50 to 60 Hz DC input voltages for RPS 300 12V 8 5A DC input voltages for RPS 675 12V 8 5A Power consumption 75W 256 BTUs per hour Power rating 0 075 kVA Physical Dimensions Weight 9 1 lb 4 1 kg Dimensions H x D x W 1 73 x 11 83 x 17 5 in 4 39 x 30 05 x 44 45 cm Table A 9 Catalyst 3750 Switch Agency Approvals Safety EMC UL to UL 60950 Third Edition FCC Part 15 Class A c UL t...

Страница 159: ...A 9 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Appendix A Technical Specifications CE Marking CE MIC Table A 9 Catalyst 3750 Switch Agency Approvals continued Safety EMC ...

Страница 160: ...Appendix A Technical Specifications A 10 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 161: ... I X B Connector and Cable Specifications This appendix describes the Catalyst 3750 switch ports and the cables and adapters that you use to connect the switch to other devices Connector Specifications These sections describe the connectors used with the Catalyst 3750 switches ...

Страница 162: ...00 1000 Ethernet ports on Catalyst 3750 switches use standard RJ 45 connectors and Ethernet pinouts with internal crossovers Figure B 2 and Figure B 1 show the pinouts Figure B 1 10 100 Port Pinouts Figure B 2 10 100 1000 Port Pinouts H5318 2 3 1 4 5 6 7 8 Pin Label 1 2 3 4 5 6 7 8 RD RD TD NC NC TD NC NC 60915 2 3 1 4 5 6 7 8 Pin Label 1 2 3 4 5 6 7 8 TP0 TP0 TP1 TP2 TP2 TP1 TP3 TP3 ...

Страница 163: ... uplink ports Refer to the Catalyst 3750 release notes for a list of supported SFP modules Figure B 3 Fiber Optic SFP Module LC Connector Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments Figure B 4 Copper SFP Module RJ 45 Connector 58476 60915 2 3 1 4 5 6 7 8 Pin Label 1 2 3 4 5 6 7 8 TP0 TP0 T...

Страница 164: ...or Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not stare into beams or view directly with optical instruments Console Port The console port uses an 8 pin RJ 45 connector which is described in Table B 1 and Table B 2 The supplied RJ 45 to DB 9 adapter cable is used to connect the console port of the switch to a console PC You need to provide a RJ 45 to...

Страница 165: ...es and adapters used with Catalyst 3750 switches Two Twisted Pair Cable Pinouts Figure B 6 and Figure B 7 show the schematics of two twisted pair cables for 10 100 ports Figure B 6 Two Twisted Pair Straight Through Cable Schematic Figure B 7 Two Twisted Pair Crossover Cable Schematic Switch 3 TD 6 TD 1 RD 2 RD Router or PC 3 RD 6 RD 1 TD 2 TD H5578 Switch 3 TD 6 TD 1 RD 2 RD Switch 3 TD 6 TD 1 RD ...

Страница 166: ...show the schematics of four twisted pair cables for 10 100 ports Figure B 8 Four Twisted Pair Straight Through Cable Schematic for 10 100 Ports Figure B 9 Four Twisted Pair Crossover Cable Schematic for 10 100 Ports 1 RD 2 RD 3 TD 6 TD 1 TD Switch Router or PC 2 TD 3 RD 6 RD 4 NC 5 NC 7 NC 8 NC 4 NC 5 NC 7 NC 8 NC 65271 1 RD 2 RD 3 TD 6 TD 1 RD Switch Switch 2 RD 3 TD 6 TD 4 NC 5 NC 7 NC 8 NC 4 NC...

Страница 167: ...for 10 100 1000 ports on Catalyst 3750 switches Figure B 10 Four Twisted Pair Straight Through Cable Schematic for 10 100 1000 Ports Figure B 11 Four Twisted Pair Crossover Cable Schematics for 10 100 1000 and 1000BASE T SFP Module Ports 1 TPO 2 TPO 3 TP1 6 TP1 1 TP1 Switch Router or PC 2 TP1 3 TPO 6 TPO 4 TP2 5 TP2 7 TP3 8 TP3 4 TP3 5 TP3 7 TP2 8 TP2 65272 1 TPO 2 TPO 3 TP1 6 TP1 1 TP0 Switch Swi...

Страница 168: ...uts Identifying a Crossover Cable To identify a crossover cable compare the two modular ends of the cable Hold the cable ends side by side with the tab at the back The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug See Figure B 12 Figure B 12 Identifying a Crossover Cable Pin 1 H10632 Pin 8 Pin 1 ...

Страница 169: ...FP module port on the switch regardless of the type of device on the other end of the connection The Auto MDIX feature is enabled by default on switches running Cisco IOS Release 12 2 18 SE or later For releases between Cisco IOS Release 12 1 14 EA1 and 12 2 18 SE the Auto MDIX feature is disabled by default For configuration information for this feature refer to the switch software configuration ...

Страница 170: ...TE adapter and the console device Note The RJ 45 to DB 25 female DTE adapter is not supplied with the switch You can order a kit part number ACS DSBUASYN containing this adapter from Cisco Table B 2 Console Port Signaling Using a DB 25 Adapter Switch Console Port DTE RJ 45 to DB 25 Terminal Adapter Console Device Signal DB 25 Pin Signal RTS 5 CTS DTR 6 DSR TxD 3 RxD GND 7 GND GND 7 GND RxD 2 TxD D...

Страница 171: ...edures on rack mounting your switch stacking your switches or connecting to small form factor pluggable SFP or XENPAK modules see Chapter 3 Switch Installation For product overview information see Chapter 2 Product Overview These steps describe how to do a simple installation 1 Accessing the CLI page C 2 2 Taking Out What You Need page C 4 3 Stacking the Switches Optional page C 5 4 Connecting to ...

Страница 172: ...rnet port of the switch to the Ethernet port of your PC or workstation To put the switch into Express Setup mode follow the steps described in Chapter 1 Using Express Setup for powering on the switch and using Express Setup After the switch is in Express Setup mode use Telnet to connect to the switch by using the IP address 10 0 0 1 and enter the setup user EXEC command See these sections in this ...

Страница 173: ...ng the console port of the switch to the serial port on your PC or workstation and accessing the switch through a Telnet session To access the switch through the console port follow these steps Taking Out What You Need section on page C 4 Connecting to the Console Port section on page C 7 Starting the Terminal Emulation Software section on page C 9 Connecting to a Power Source section on page C 9 ...

Страница 174: ...hown in Figure C 1 from the shipping container Figure C 1 The Catalyst 3750 Switch Adapter Cable AC Power Cord and the StackWise Cable 1 Catalyst 3750 switch 3 AC power cord 2 RJ 45 to DB 9 adapter cable 4 StackWise cable optional Catalyst 3750 SERIES SYST RPS MASTR STAT DUPLX SPEED STACK MODE 13X 14X 23X 24X 1X 2X 11X 12X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 9053...

Страница 175: ...e of device on the other end of the connection The Auto MDIX feature is enabled by default on switches running Cisco IOS Release 12 2 18 SE or later For releases between Cisco IOS Release 12 1 14 EA1 and 12 2 18 SE the Auto MDIX feature is disabled by default For configuration information for this feature refer to the switch software configuration guide or the switch command reference Stacking the...

Страница 176: ...ed StackWise cable to connect the switches Step 2 Use the window in the StackWise cable to align the connector correctly Secure the screws tightly Step 3 Insert the other end of the cable into the connector of the other switch and secure the screws tightly See the Connecting StackWise Cable to StackWise Ports section on page 3 38 for detailed installation procedures on how to connect the switches ...

Страница 177: ...er cable Note If you have stacked your switches connect to the console port of one of the switches in the stack The initial configuration for the entire stack can be performed on any switch in the stack Follow these steps to connect the PC or terminal to the switch Step 1 Using the supplied RJ 45 to DB 9 adapter cable insert the RJ 45 connector into the console port on the rear of a switch as show...

Страница 178: ...lyst 3750 switches 3 RJ 45 to DB 9 adapter cable 2 Power cord RATIN G 100 20 0V 1 6A 0 9A 50 60 HZ DC INPUT S FOR REMO TE POWE R SUPPLY SPECIFIED IN MANU AL 12v 8 5a CONSOLE RATIN G 100 20 0V 1 6A 0 9A 50 60 HZ DC INPUT S FOR REMO TE POWE R SUPPLY SPECIFIED IN MANU AL 12v 8 5a CONSOLE RATIN G 100 20 0V 1 6A 0 9A 50 60 HZ DC INPUT S FOR REMO TE POWE R SUPPLY SPECIFIED IN MANU AL 12v 8 5a CONSOLE 1 ...

Страница 179: ...switch and your PC or terminal possible Step 1 Start the terminal emulation program if you are using a PC or terminal Step 2 Start a terminal emulation session Step 3 Configure the baud rate and character format of the PC or terminal to match these console port default characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Connecting to a Power Source Follow these steps to co...

Страница 180: ...Speed and the Stack LEDs turn green On the Catalyst 3750 24PS and 3750 48PS switches the Power over Ethernet PoE LED also turns green as POST begins The System LED flashes green and the other LEDs remain continuous green When POST completes successfully the System LED remains green The RPS LED remains green for some time and then returns to its operating status The other LEDs turn off and return t...

Страница 181: ...s also required if you plan to use the Cluster Management Suite CMS to configure and manage the switch IP Settings You will need this information from your network administrator before you complete the setup program Switch IP address Subnet mask IP netmask Default gateway router Enable secret password Enable password Telnet password Completing the Setup Program Note If your switches are stacked an...

Страница 182: ...ot use n where n is a number as the last character in a host name for any switch Enter host name Switch host_name Step 3 Enter an enable secret password and press Return The password can be from 1 to 25 alphanumeric characters can start with a number is case sensitive allows spaces but ignores leading spaces The secret password is encrypted and the enable password is in plain text Enter enable sec...

Страница 183: ...ask for this interface 255 0 0 0 255 0 0 0 Step 9 Enter Y to configure the switch as the cluster command switch Enter N to configure it as a member switch or as a standalone switch If you enter N the switch appears as a candidate switch in the CMS You can configure the switch as a command switch later through the CLI or CMS interface To configure it later type no Would you like to enable as a clus...

Страница 184: ...nd use it the next time the switch reboots save it in nonvolatile RAM NVRAM by selecting option 2 Enter your selection 2 2 Make your selection and press Return After you complete the setup program the switch can run the default configuration that you created If you want to change this configuration or want to perform other management tasks use one of these tools Command line interface CLI CMS from...

Страница 185: ...h only the Cisco RPS model PWR300 AC RPS N1 to the RPS receptacle Waarschuwing Slechts de Cisco RPS model PWR300 AC RPS N1 aan de RPS contactdoos verbinden Varoitus Kiinnitä RPS vastakappaleeseen vain Cisco RPS malli PWR300 AC RPS N1 Avertissement Raccordez le bloc d alimentation Cisco RPS modèle PWR300 AC RPS N1 uniquement au connecteur RPS Warnung An die RPS Steckhülse darf nur das Cisco RPS Mod...

Страница 186: ...ation Guide 78 15136 03 Advarsel Koble bare Cisco RPS modell PWR300 AC RPS N1 til RPS stikkontakten Aviso Anexe o RPS Cisco modelo PWR300 AC RPS N1 apenas ao receptáculo RPS Advertencia Sólo conecte el Cisco RPS modelo PWR300 AC RPS N1 al receptáculo RPS Varning Koppla endast Ciscos RPS modell PWR300 AC RPS N1 till RPS uttaget ...

Страница 187: ...S malli PWR675 AC RPS N1 Avertissement Raccordez le bloc d alimentation Cisco RPS modèle PWR675 AC RPS N1 uniquement au connecteur RPS Warnung An die RPS Steckhülse darf nur das Cisco RPS Modell PWR675 AC RPS N1 angeschlossen werden Avvertenza Collegare soltanto il Cisco RPS modello PWR675 AC RPS N1 alla presa RPS Advarsel Koble bare Cisco RPS modell PWR675 AC RPS N1 til RPS stikkontakten Aviso An...

Страница 188: ...n PoE Power over Ethernet circuits als er verbindingen worden gemaakt met blootliggende metalen contactpunten geleiders of aansluitingspunten die niet zijn geïsoleerd Gebruik dit type verbinding niet tenzij de blootliggende metalen onderdelen zich bevinden op een locatie met beperkte toegang en de gebruikers en onderhoudstechnici die toegang tot deze locatie hebben op het gevaar worden gewezen De ...

Страница 189: ... beschränktem Zugang und Personen die Zugang dazu haben sind ausdrücklich über diese Gefahr informiert worden Ein Ort mit beschränktem Zugang ist nur mit Hilfe eines speziellen Werkzeugs Schloss und Schlüssels oder anderen Sicherheitseinrichtungen zugänglich Avvertenza Nei circuiti con alimentazione via Ethernet PoE possono verificarsi pericoli di scosse elettriche se si creano connessioni con con...

Страница 190: ... interconexiones se utilizan contactos conductores o terminales metálicos descubiertos Evite tales métodos de interconexión a menos que las partes metálicas descubiertas se encuentren en un lugar de acceso restringido y tanto los usuarios como el personal de servicios en dicho lugar sean conscientes de la existencia de tal riesgo Sólo se puede tener acceso a una zona de acceso restringido mediante...

Страница 191: ...D 7 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Appendix D Translated Safety Warnings Shock Hazard From Interconnections ...

Страница 192: ...intenance de ces équipements à des personnels qualifiés et expérimentés Warnung Das Installieren Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden Avvertenza Questo apparato può essere installato sostituito o mantenuto unicamente da un personale competente Advarsel Bare opplært og kvalifisert personell skal foreta installasjoner utskiftninger e...

Страница 193: ... brancher le système sur la source d alimentation consulter les directives d installation Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all alimentatore Advarsel Les installasjonsinstruksjonene før systemet kobles til strømkilden Aviso Leia as instruções de instalação ...

Страница 194: ...rden warm wanneer ze met stroom en aarde zijn verbonden en kunnen ernstige brandwonden veroorzaken of het metalen voorwerp aan de aansluitklemmen lassen Varoitus Ennen kuin työskentelet voimavirtajohtoihin kytkettyjen laitteiden parissa ota pois kaikki korut sormukset kaulakorut ja kellot mukaan lukien Metalliesineet kuumenevat kun ne ovat yhteydessä sähkövirran ja maan kanssa ja ne voivat aiheutt...

Страница 195: ... til kraftledninger Metallgjenstander som er koblet til kraftledninger og jord blir svært varme og kan forårsake alvorlige brannskader eller smelte fast til polene Aviso Antes de trabalhar em equipamento que esteja ligado a linhas de corrente retire todas as jóias que estiver a usar incluindo anéis fios e relógios Os objectos metálicos aquecerão em contacto com a corrente e em contacto com a ligaç...

Страница 196: ...te worden Als het chassis mocht vallen kan dit ernstig lichamelijk letsel en beschadiging van de apparatuur veroorzaken Varoitus Älä aseta asennuspohjaa minkään muun laitteen päälle Asennuspohja voi pudotessaan aiheuttaa vaikean ruumiinvamman tai laitevaurion Avertissement Ne placez pas ce châssis sur un autre appareil En cas de chute il pourrait provoquer de graves blessures corporelles et d impo...

Страница 197: ...å annet utstyr Hvis kabinettet faller kan det forårsake alvorlig skade på mennesker og utstyr Aviso Não coloque o chassis em cima de qualquer outro equipamento Se o chassis cair poderá causar ferimentos graves e danos no equipamento Atención No apilar los chasis sobre ningún otro equipo Si el chasis se cae al suelo puede causar graves lesiones físicas y daños al equipo Varning Placera inte chassit...

Страница 198: ...sible à tout moment parce qu elle fait office de système principal de déconnexion Warnung Der Netzkabelanschluß am Gerät muß jederzeit zugänglich sein weil er als primäre Ausschaltvorrichtung dient Avvertenza Il gruppo spina presa deve essere sempre accessibile poiché viene utilizzato come dispositivo di scollegamento principale Advarsel Kombinasjonen støpsel uttak må alltid være tilgjengelig ette...

Страница 199: ...eisto on tarkoitettu maadoitettavaksi Varmista että isäntälaite on yhdistetty maahan normaalikäytön aikana Attention Cet équipement doit être relié à la terre S assurer que l appareil hôte est relié à la terre lors de l utilisation normale Warnung Dieses Gerät muß geerdet werden Stellen Sie sicher daß das Host Gerät während des normalen Betriebs an Erde gelegt ist Avvertenza Questa apparecchiatura...

Страница 200: ...ue el equipo principal esté conectado a tierra durante el uso normal Varning Denna utrustning är avsedd att jordas Se till att värdenheten är jordad vid normal användning Warning When installing or replacing the unit the ground connection must always be made first and disconnected last Waarschuwing Bij installatie of vervanging van het toestel moet de aardverbinding altijd het eerste worden gemaak...

Страница 201: ...rennt werden Avvertenza In fase di installazione o sostituzione dell unità eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo Advarsel Når enheten installeres eller byttes må jordledningen alltid tilkobles først og frakobles sist Aviso Ao instalar ou substituir a unidade a ligação à terra deverá ser sempre a primeira a ser ligada e a última a ser desligada Advertencia Al...

Страница 202: ...stön enimmäislämpötilaksi suositellun 45 C Jätä vähintään 7 6 cm n vapaa tila tuuletusaukkojen ympärille jotta ilma pääsee vapaasti virtaamaan Attention Pour éviter une surchauffe du commutateur ne pas le faire fonctionner dans un local dont la température ambiante dépasse le maximum recommandé de 45 C 113 F Pour faciliter la circulation d air aménager un dégagement d au moins 7 6 cm 3 pouces auto...

Страница 203: ...xima de 45 C Para evitar o bloqueamento da circulação de ar deixe pelo menos um espaço de 7 6 cm em volta das aberturas de ventilação Advertencia Para evitar que el interruptor se recaliente no se debe usar en áreas cuya temperatura ambiente exceda la máxima recomendada esto es 45 C 113 F Para no entorpecer la corriente de aire dejar por lo menos 7 6 cm 3 pulgadas de espacio muerto alrededor de la...

Страница 204: ...rken of kabels aan te sluiten of te ontkoppelen Varoitus Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla Attention Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage Warnung Arbeiten Sie nicht am System und schließen Sie keine Kabel an bzw trennen Sie keine ab wenn es gewittert Avvertenza Non lavorare sul sistema o collegare...

Страница 205: ...sconectar cables durante el transcurso de descargas eléctricas en la atmósfera Varning Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar Warning Ultimate disposal of this product should be handled according to all national laws and regulations Waarschuwing Het uiteindelijke wegruimen van dit product dient te geschieden in overeenstemming met alle nationale w...

Страница 206: ...te gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Avvertenza Lo smaltimento di questo prodotto deve essere eseguito secondo le leggi e regolazioni locali Advarsel Endelig kassering av dette produktet skal være i henhold til alle relevante nasjonale lover og bestemmelser Aviso Deitar fora este produto em conformidade com todas as leis e regulamentos nacionais Advertencia Al deshacerse po...

Страница 207: ...smaatregelen nemen om ervoor te zorgen dat het toestel stabiel blijft De onderstaande richtlijnen worden verstrekt om uw veiligheid te verzekeren Dit toestel dient onderaan in het rek gemonteerd te worden als het toestel het enige in het rek is Wanneer u dit toestel in een gedeeltelijk gevuld rek monteert dient u het rek van onderen naar boven te laden met het zwaarste onderdeel onderaan in het re...

Страница 208: ...Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen Wenn diese Einheit die einzige im Gestell ist sollte sie unten im Gestell angebracht werden Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das Gestell von unten nach oben zu laden wobei das schwerste Bauteil unten im Gestell anzubringen ist Wird das Gestell mit Stabilisierungszubehör geliefert sind z...

Страница 209: ... um suporte estável As seguintes directrizes ajudá lo ão a efectuar o seu trabalho com segurança Esta unidade deverá ser montada na parte inferior da estante caso seja esta a única unidade a ser montada Ao montar esta unidade numa estante parcialmente ocupada coloque os itens mais pesados na parte inferior da estante arrumando os de baixo para cima Se a estante possuir um dispositivo de estabiliza...

Страница 210: ...iktighetsåtgärder för att försäkra dig om att systemet står stadigt Följande riktlinjer ges för att trygga din säkerhet Om denna enhet är den enda enheten på ställningen skall den installeras längst ned på ställningen Om denna enhet installeras på en delvis fylld ställning skall ställningen fyllas nedifrån och upp med de tyngsta enheterna längst ned på ställningen Om ställningen är försedd med sta...

Страница 211: ...em RPS is not connected to the switch install an RPS connector cover on the back of the switch Statement 265 Waarschuwing Als er geen redundant voedingssysteem RPS aan de schakelaar is gekoppeld dient u een RPS connectorkapje op de achterkant van de schakelaar te installeren Varoitus Jos korvautuvaa tehojärjestelmää redundant power system RPS ei ole liitetty kytkimeen kiinnitä RPS liittimen suojus...

Страница 212: ...ndante non è collegato al dispositivo switch installare un copri connettore RPS sul retro del switch Advarsel Dersom et redundant strømsystem Redundant Power System RPS ikke er koblet til bryteren skal det installeres et RPS koblingsdeksel på baksiden av bryteren Aviso Se um sistema de alimentação redundante RPS não estiver conectado a um switch instale uma capa de conector RPS na parte de trás do...

Страница 213: ...itetään seinään etupaneeli ylöspäin Attention Pour satisfaire aux dispositions de sécurité installez les commutateurs muraux avec le panneau frontal vers le haut Warnung Zur Einhaltung der Sicherheitsvorschriften die Schalter so an einer Wand montieren dass die Frontplatte nach oben zeigt Avvertenza In conformità ai regolamenti di sicurezza installare i dispositivi switch a muro con il pannello fr...

Страница 214: ...d for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Waarschuwing Deze eenheid is bestemd voor installatie in plaatsen met beperkte toegang Toegang tot een dergelijke plaats kan alleen verkregen worden door middel van een speciaal instrument een slot en sleutel of een ander veiligheidsm...

Страница 215: ...o e chiave o altri dispositivi di sicurezza Advarsel Denne enheten er beregnet på installasjon i områder med begrenset tilgang Et begrenset tilgangsområde kan bare nås ved hjelp av et spesielt verktøy lås og nøkkel eller andre sikkerhetsanordninger Aviso Esta unidade foi concebida para instalação em áreas de acesso restrito Uma área de acesso restrito é uma área à qual apenas tem acesso o pessoal ...

Страница 216: ...t Varoitus Ethernet kaapelit täytyy suojata kun niitä käytetään yleisessä toimistoympäristössä Attention Pour une utilisation en site central les câbles Ethernet doivent être impérativement blindés Warnung Ethernet Kabel müssen abgeschirmt werden wenn sie in einer Zentrale eingesetzt werden Avvertenza I cavi Ethernet devono essere schermati se utilizzati in un ambiente di ufficio centrale Advarsel...

Страница 217: ...en estar protegidos cuando se usen dentro de una oficina central Varning Ethernetkablar måste vara avskärmade vid användning i central kontorsmiljö Warning Class 1 laser product Waarschuwing Klasse 1 laser produkt Varoitus Luokan 1 lasertuote Attention Produit laser de classe 1 Warnung Laserprodukt der Klasse 1 Avvertenza Prodotto laser di Classe 1 Advarsel Laserprodukt av klasse 1 ...

Страница 218: ...Translated Safety Warnings Class 1 Laser Product D 34 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 Aviso Produto laser de classe 1 Advertencia Producto láser Clase I Varning Laserprodukt av klass 1 ...

Страница 219: ...e blootstelling aan de laserstraal Varoitus Vältä säteelle altistumista Attention Éviter toute exposition directe au faisceau Warnung Schützen Sie sich vor direkter Laserbestrahlung Avvertenza Evitare l esposizione diretta al raggio laser Advarsel Unngå direkte eksponering til laserstrålen Aviso Evite exposição a raios laser Advertencia Evite la exposición directa al haz del láser Varning Utsätt d...

Страница 220: ...oitus Irrotetuista kuiduista tai liittimistä voi tulla näkymätöntä lasersäteilyä Älä tuijota säteitä tai katso niitä suoraan optisilla välineillä Attention Les fibres ou connecteurs débranchés risquent d émettre des rayonnements laser invisibles à l œil Ne regardez jamais directement les faisceaux laser à l œil nu ni d ailleurs avec des instruments optiques Warnung Unterbrochene Fasern oder Stecke...

Страница 221: ...trument Aviso Radiação laser invisível pode ser emitida de conectores ou fibras desconectadas Não olhe diretamente para os feixes ou com instrumentos ópticos Advertencia Es posible que las fibras desconectadas emitan radiación láser invisible No fije la vista en los rayos ni examine éstos con instrumentos ópticos Varning Osynlig laserstrålning kan avges från frånkopplade fibrer eller kontaktdon Ri...

Страница 222: ...Appendix D Translated Safety Warnings Laser Radiation D 38 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...

Страница 223: ... and 24 inch racks 3 19 A AC power connecting to 3 12 connector 2 25 specifications A 1 to A 8 adapter cable 3 11 adapter pinouts terminal RJ 45 to DB 25 B 10 RJ 45 to DB 9 B 9 agency approvals A 8 altitude operating and storage A 1 to A 8 autonegotiation 2 8 2 11 B brackets See mounting brackets C cable guide attaching 3 31 cable lengths 3 7 cables crossover four twisted pair pinout 10 100 ports ...

Страница 224: ...C 2 accessing through console port C 3 Cluster Management Suite See CMS CMS 2 28 command line interface See CLI connecting to 10 100 1000 ports 3 51 to 10 100 ports 3 51 to console port 3 10 B 4 to SFP modules 3 55 to 3 59 to XENPAK modules 3 59 to 3 60 connecting to the console port C 7 connection procedures 3 51 to 3 60 connectivity problems solving 4 4 connectors and cables console port B 4 to ...

Страница 225: ... 3 front panel 10 100 1000 ports 2 11 10 100 ports 2 8 clearance 3 8 description 2 4 to 2 6 LEDs 2 13 to 2 21 SFP module ports 2 12 to 2 13 XENPAK module ports 2 3 2 13 G Grounded D 15 grounded equipment warning D 15 H HP OpenView 2 28 humidity relative A 1 to A 8 I installation assigning the IP Address C 11 connecting to a power source C 9 rack mounting 3 19 to 3 38 site requirements 3 7 stacking...

Страница 226: ...aster 2 17 port 2 17 to 2 21 port mode 2 17 to 2 21 POST results 4 2 Power over Ethernet 2 18 RPS 2 16 to 2 17 speed 2 18 stack 2 21 STATUS 2 18 system 2 16 troubleshooting with 4 4 lightning activity warning D 20 M main disconnecting device warning D 14 mode button 2 13 mounting table or shelf 3 37 mounting wall mounting 3 33 mounting brackets attaching 3 21 to 3 29 rack mount 3 29 N noise electr...

Страница 227: ... to 2 21 port modes changing 2 13 LEDs 2 17 to 2 18 See also mode button ports 10 100 2 8 pinouts B 2 recommended cables 3 52 10 100 1000 2 4 pinouts B 2 recommended cables 3 52 numbering of 10 100 2 8 numbering of 10 100 1000 2 11 numbering of SFP module ports 2 7 to 2 8 POST LEDs 4 2 results 4 1 running at powerup 1 5 3 13 4 2 C 10 power connecting to 3 12 connectors 2 23 2 25 specifications A 1...

Страница 228: ...SE T supported speeds 2 20 bale clasp latch removal 3 44 connecting to 3 55 to 3 59 connectors B 3 described 2 12 to 2 13 installation 3 42 to 3 44 shelf mounting 3 37 Simple Network Management Protocol See SNMP SNMP network management platforms 2 28 software switch management 2 28 specifications A 1 stacking cabling considerations 3 15 connecting to a StackWise port 3 14 examples 3 14 planning co...

Страница 229: ...accessing the CLI 2 28 temperature operating A 1 terminal connecting to switch 3 11 terminal emulation software 3 10 C 9 translated warnings D 1 to D 36 troubleshooting 4 1 to 4 7 W wall mounting 3 33 warnings defined xvi installation 3 2 translated D 1 to D 36 X XENPAK modules 2 3 2 13 connecting to 3 59 to 3 60 installation 3 46 to 3 49 removal 3 49 ...

Страница 230: ...Index IN 8 Catalyst 3750 Switch Hardware Installation Guide 78 15136 03 ...