SOLUTION OF THE PROBLEMS
Problem
Water doesn’t come out of
the tap
The water supply doesn’t
close
The water flow has been
diminished
Indication
The sensor flashes
continuously when the
hands of the user are within
the action range
Low battery load level
Replace the battery
The sensor doesn’t flash
when the hands of the user
are within the action range
Unsuitable action range
The sensor flashes when the
hands of the user are within
the action range
The sensor receives
reflections from a mirror or
another object
Debris, scaling or damages
in the solenoid valve
The feeding pressure is
higher than 5 bar
Remove the cause of the
reflection
Disassemble the solenoid
valve, check the running
and clean or replace
eventually
Reduce the feeding pressure
Damaged electronic part
The sensor flashes when the
hands of the user are within
the action range
Debris, scaling or damages
in the solenoid valve
Disassemble the solenoid
valve, check the running
and clean or replace
eventually.
The sensor also flashes
when the action range is
free
The sensor receives
reflections from a mirror or
another object.
Remove the cause of the
reflection
The sensor doesn’t flash
when the hands of the user
are within the action range
The sensor is dirty or is
hidden
The sensor receives
reflections from a mirror or
another object
Clean or remove possible
interferences
Remove the cause of the
reflection
Damaged electronic part
Replace the electronic part
The aerator or the feeding
filters are dirty or stopped
Check, clean and replace
eventually
Replace the electronic part
Run up battery load level
The sensor is dirty or is
hidden
Adjust the sensor sensitivity
Replace the battery
Clean or remove possible
interferences
Cause