75
Instruction Manual
SVGm
10�2�- COOLING FANS
The cooling fans must operate correctly to avoid overheating in the static generator
components.
The device has high-speed cooling fans, with an estimated useful life of 40000 hours.
Nevertheless, this useful life can be shortened depending on the conditions of use (temperature, hu-
midity, environmental pollution). In the event that the fans lose their efficiency, the device’s perfor-
mance will deteriorate.
The following symptoms in the static generator behaviour could indicate a deterioration of the fans:
Increase in fan noise.
Increase in temperature of the device under the same environmental conditions and load.
The
SVGm
regularly indicates a temperature alarm.
The set of fans must be replaced if they have exceeded their useful life or show signs of deterioration.
In such cases,
CIRCUTOR
will provide a spare part that consists of a set of fans so that the device can
be repaired quickly and easily.
For an installation with devices in parallel, all of the fans must be changed at the same
time.
10�3�-
CHANGE OF COOLING FANS: SVGm OF 20�7 and 30 kvar
Table 36: Tools needed (SVGm-3WF-030M and SVGm-4WF-020M)
Tools needed
Fan assembly replacement
SVGm-3WF-030M and SVGm-4WF-020M, Code: 920121
2
Screwdriver for
PH2
head screws
3
Screwdriver for
Allen 3
head screws
Figure 76: Location of the cooling fans�
Содержание SVGm-3WF-100C-480
Страница 1: ...SVGm M248B01 03 21A Static var generator INSTRUCTION MANUAL ...
Страница 2: ...2 SVGm Instruction Manual ...
Страница 98: ...98 SVGm Instruction Manual 14 CE CERTIFICATE ...
Страница 99: ...99 Instruction Manual SVGm ...
Страница 100: ...100 SVGm Instruction Manual ...
Страница 101: ...101 Instruction Manual SVGm ...