Product Description
48
TT Twin-Screw Pump -
Installation, Operation & Maintenance Manual
• Running a pump without safety devices exposes operators to risk of serious personal injury
or death. Never operate a unit unless appropriate safety devices (guards, etc.) are properly
installed.
• Avoid death or serious injury. Assure mechanical seal guard is properly installed using
supplied fastening hardware.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installation
or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for
specific instructions and recommendations.
Bearing lubrication
Precautions
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure
That the bearings are properly lubricated prior to startup.
Pumps are shipped without oil
You must lubricate the NDE gears and bearings at the job site. The gear and bearing
housings are supplied with sight glasses. Make sure that the oil level is set to the center
of the sight glass when the pump is not running. (A false level reading can occur while
the pump is running).