12.3
OCPP 1.6 COMMON ERRORS
After applying new settings, please go to the following URL from Charge Point in order
to check the proper connection of the integration chosen:
http://<IP>/services/cpi/log?app=ocpp1.6
Look especially for the following messages:
If
‘BootNotication result: Accepted”
:
Charge Point is properly connected to the Central
System.
Otherwise, if the message shown is
‘Registering CB in the CS: failed’
,
check the
following list of errors and refer to the following URL:
http://<IP>:8080/html/setup.html
12.3.1
CS Connection FAILED. Fail reason: Underlying Transport Error
Hostname cannot be resolved in the Charge Point side:
The host URL introduced is not correct. Check it in the OCPP configuration.
•
Check if embedded the modem is connected to the network. Otherwise, check
modem parameters (some cellular providers require special APN configuration).
•
If there is no modem, ethernet IP address shall be static, using the gateway and
DNS from this network. Do not use DHCP=ON.
12.3.2
CS Connection FAILED. Fail reason: Timer Expired
Charge Point has resolved the DNS of the URL but it is not able to reach CS.
•
Check if the embedded modem is connected to the network. Otherwise, check
modem parameters (some SIM card providers require special APN
configuration).
•
If there is no modem, then ethernet IP address must be static, using gateway and
DNS from this network. Do not use DHCP=ON.
12.3.3
CS Connection FAILED. Fail reason: Invalid HTTP status
The Charge Point reaches the CS, but it has rejected the Charge Point ID configured.
•
CS should check if Charge Point has been added in their side.
•
Check Charge Point ID in the OCPP configuration on CP side.