SERVICE MANUAL
–
Post eVolve Smart
9 - OPTIONAL DEVICES
CIRCONTROL, S.A.
–
Innovació, 3
–
08232
–
Viladecavalls (Barcelona)
Tel.: +34 937 362 940
–
Fax: +34 937 362 941
58
Web: www.circontrol.com
–
E-mail:
9.5.3.3
CCL1-MINI WIRING
Following image shows a detailed schematic of the connections in the CCL1-MINI PCB.
Please, refer to “
” section for more details.
RA
RB
LKA
LKB
9.6
SURGE PROTECTION (21,23)
The surge protection has the capacity of discharging induced voltage surges. Suitable
for the second level of protections in the supply distribution panels, in which Type I
protectors are installed, or for the first level of protection for applications not exposed to
direct strikes and with no external lightning protection system as defined by IEC 61643-
11.
9.6.1
SURGE PROTECTION DEVICE
General
Dimensions (HxWxL)
9x 7,2x 7
Num. poles
4
Weight
432gr
Network config.
TT, TNS
Designation according IEC 61643-11 Class II Temperature range -40ºC+85ºC