background image

 

 

Содержание Post eVolve Smart Series

Страница 1: ......

Страница 2: ...n be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be acc...

Страница 3: ...INTEGRATED EMBEDDED DEVICE 14 6 1 1 CCL1 MINI IN OUTS 15 6 1 2 TECHNICAL CHARACTERISTICS 16 7 CHARGE POINT SLAVE DEVICES 17 7 1 MODE 3 CHARGE CONTROLLER 13 17 7 1 1 WIRING CONNECTION 17 7 1 2 DEVICE...

Страница 4: ...4 8 4 2 CCL1 MINI WIRING 44 8 5 INTERFACE RGB BEACON LED CONVERTER BOARDS 29 45 8 5 1 LED BOARD WIRING CONNECTION 45 8 5 2 LED BOARD WIRING CONNECTION TO CCL1 MINI 46 9 OPTIONAL DEVICES 47 9 1 LOCKING...

Страница 5: ...MCB 75 12 2 OCPP 1 5 COMMON ERRORS 76 12 2 1 Connect failed in tcp_connect 76 12 2 2 Notifying Boot 200 77 12 2 3 Notifying Boot 1 77 12 2 4 HTTP 1 1 404 Not Found 77 12 2 5 Cannot get charge device...

Страница 6: ...7 362 941 4 Web www circontrol com E mail circontrol circontrol com 14 8 MODEL C63 ONE 96 14 9 MODEL TM4 97 15 WIRING DIAGRAMS PHASE II 98 15 1 MODEL T 98 15 2 MODEL T RECLOSING V1 105 15 3 MODEL T RE...

Страница 7: ...or events arising from such breach THE FOLLOWING SYMBOLS ARE USED FOR IMPORTANT SAFETY INSTRUCTIONS IN THIS DOCUMENT Before performing any maintenance repair or manipulation of any equipment connectio...

Страница 8: ...with non conducting handles when working on electrical devices 4 Never use metallic pencils or rulers or wear rings or metal watchbands when working with electrical equipment 5 When it is necessary t...

Страница 9: ...fy this unit If modified CIRCONTROL will reject all responsibility and the warranty will be void Comply strictly with current safety regulations according to your country rules Do not make repairs or...

Страница 10: ...e is charging Light beacon Three colour LED indicates the status of the connectors RFID User identification Ethernet TCP IP communication for remote supervision and configuration 3G Modem optional For...

Страница 11: ...different versions of its internal components distribution called phase I and phase II The main purpose of these changes is to upgrade the components and optimise the inner space distribution Other mi...

Страница 12: ...ing system Plug B 6 N A 7 Socket type 2 Plug A 8 Socket type 2 Plug B 9 N A 10 control MCB 11 N A 12 N A 13 Mode 3 DIN Rail 14 Control power supply 15 N A 16 Current plug contactors 17 Energy meters 1...

Страница 13: ...Socket type 2 Plug B 9 Control power supply 10 Control MCB 11 Socket CEE 7 3 Plug A 12 Socket CEE 7 3 B 13 Mode 3 DIN rail 14 Control power supply 15 MCB CEE 7 3 16 Contactor CEE 7 3 17 Energy meters...

Страница 14: ...components if are replaced All devices are interconnected via RS 485 with the master CCL1 MINI 3 In this configuration the master device CCL1 MINI is centrally located along the set of RS 485 wires th...

Страница 15: ...number Setup Baud rate RS 485 PORT A 1 RS 485 PORT B 2 Device Meter Plug A Mode 3 Rail DIN Plug A LCD display RFID card reader Mode 3 Rail DIN Plug B Meter Plug B 17 A 13 A 26 27 13 B 17 B Peripheral...

Страница 16: ...e Point and the most important element because it is specially designed to manage the Charge Point and all the scenarios of charge transaction There are two different models of CCL1 MINI device CCL1 M...

Страница 17: ...beacon lights and the antivandal doors The digital inputs are intended for different functions Digital inputs 1 Digital inputs to detect the status of the CEE 3 7 sockets Digital inputs 2 Digital inp...

Страница 18: ...ying the two serial ports available on CCL1 MINI RS485 port A Pin A brown Pin B White RS485 port B Pin A brown Pin B White Ethernet port and embedded modem and GPRS antenna They are dedicated to acces...

Страница 19: ...y meter 17 LCD DISPLAY 26 RFID READER 27 7 1 MODE 3 CHARGE CONTROLLER 13 Mode 3 DIN rail is the gateway of mode 3 communications and allows charging an electrical vehicle as defined in IEC 61851 1 7 1...

Страница 20: ...nguishing Protection IP20 Dimensions 35 x 73 x 84 68mm SERIAL Type RS 485 Baud rate supported 4800 9600 19200 34800 57600bps Default peripheral number 96 Default baud rate 9600bps 7 1 4 ADDITIONAL INF...

Страница 21: ...nt parameters because it is integrated in the same device The CEM M RS 485 device is a communication gateway between the CEM C10 and the local controller 7 2 1 1 DEVICE CONFIGURATION PROCEDURE STEP AC...

Страница 22: ...19200 13 Press two times to arrive to DONE wait for BAUD to appear 14 Press five times to arrive to RETURN 15 Press and hold button from CEM C10 for at least 2 seconds to SETUP 16 Press two times to a...

Страница 23: ...4 section for more details 7 2 1 4 CCL1 MINI WIRING CONNECTION Following image shows a detailed schematic of the connections in the CCL1 MINI PCB Please refer to TECHNICAL DATA section for more detail...

Страница 24: ...1 DEVICE CONFIGURATION PROCEDURE STEP ACTION 1 Press and hold button from CEM C20 for at least 2 seconds 2 Press several times until reach SETUP 3 Press and hold button from CEM C20 for at least 2 se...

Страница 25: ...e to RETURN 15 Press and hold button from CEM C20 for at least 2 seconds to SETUP 16 Press two times to arrive to RETURN 17 Press and hold button from CEM C20 for at least 2 seconds 7 2 2 2 TECHNICAL...

Страница 26: ...he connections in the CCL1 MINI PCB and in each Plug Please refer to 7 2 1 4 section for more details 7 2 2 4 CCL1 MINI WIRING CONNECTION Following image shows a detailed schematic of the connections...

Страница 27: ...s a single phase two wire with RS 485 DIN rail electronic meter This meter complies with EN50470 1 3 standards It can measure the active and reactive energy consumption 7 2 3 1 WIRING CONNECTION Follo...

Страница 28: ...2 CCL1 MINI WIRING CONNECTION Following image shows a detailed schematic of the connections in the CCL1 MINI PCB Please refer to TECHNICAL DATA section for more details 7 2 4 THREE PHASE YTL METER PH...

Страница 29: ...om E mail circontrol circontrol com 7 2 4 1 LCD DISPLAY Present tariff indicator Content indicate it can be shown T1 T2 T3 T4 L1 L2 L3 Frequency display kWh unit display it can be shown kW kWh Kvarh V...

Страница 30: ...lls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 28 Web www circontrol com E mail circontrol circontrol com 7 2 4 3 TECHINCAL CHARACTERISTICS Features Voltage frequency 230 400V AC 50 Hz Accuracy c...

Страница 31: ...rt A L1 L2 L3 N B A CCL1 MINI Port B L1 L2 L3 N PLUG A PLUG B MCB Q04 1 MCB Q06 1 7 3 LCD DISPLAY 26 The LCD Display informs the end user about how to charge the EV and about the errors to maintenance...

Страница 32: ...CE CONFIGURATION PROCEDURE No additional configuration is required to operate with LCD display 7 3 4 ADDITIONAL INFORMATION INFORMATION ON POWER UP Display shows the following message when device is p...

Страница 33: ...atus indicator colour Green LED RFID configured and ready for use In this case there is no additional configuration required to operate with RFID reader Orange LED RFID not configured Follow next step...

Страница 34: ...e supported 4800 9600 19200 bps Default peripheral number 1 Default baud rate 9600 bps Standards ISO 14443 A B 7 4 1 3 WIRING CONNECTION Following image shows a detailed schematic of the connections i...

Страница 35: ...o 80 C SERIAL Type RS 232 Baud rate supported 1200 2400 4800 9600 19200 38400 57600bps Default peripheral number 1 Default baud rate 9600bps Standards LEGIC Advant LEGIC Prime ISO14443 A B compatible...

Страница 36: ...CCL1 MINI Please refer to 7 4 2 3 section for more details Picture below shows how to connect the RFID LEGIC reader to the power supply 7 4 2 3 CCL1 MINI WIRING Following image shows a detailed schema...

Страница 37: ...that can be found inside the Charge Point Modem 3 Low temperature kit 6 22 Power supply 9 Tamper switch 18 Interface RGB beacon LED converter board 29 8 1 MODEM 3 8 1 1 MODEM MODEL IDENTIFICATION Ther...

Страница 38: ...your Modem 4G 8 1 2 HARDWARE REPLACEMENT PROCEDURE only for 4G series STEP ACTION 1 Firstly switch OFF the individual derivation MCB After ensuring that the unit is not energized open the unit from th...

Страница 39: ...i 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 37 Web www circontrol com E mail circontrol circontrol com 3 Remove the following screw as shown in the following image 4 Remove...

Страница 40: ...941 38 Web www circontrol com E mail circontrol circontrol com 5 SIM card holder is in the other side of the Modem Press and remove the SIM card carefully 6 Install the new Modem being careful with th...

Страница 41: ...ature 2 Heater 22 It is a self regulating PTC element that ensures a constant temperature operation by preventing the formation of condensation 8 2 1 TECHNICAL CHARACTERISTICS 8 2 1 1 THERMOSTAT Rated...

Страница 42: ...ction for more details THERMOSTAT HEATER MCB Q03 1 8 2 3 DEVICE CONFIGURATION PROCEDURE Thermostat is installed at the top of the Charge Point Please refer to COMPONENTS OVERVIEW section for more deta...

Страница 43: ...perly if the output of power supply is not at least 12V 8 3 1 1 TECHNICAL CHARACTERISTICS A table of technical specifications of the power supply is shown below 8 3 1 2 WIRING CONNECTION Following ima...

Страница 44: ...output of power supply is not at least 5V 8 3 2 1 TECHNICAL CHARACTERISTICS A table of technical specifications of the power supply is shown below 8 3 2 2 WIRING CONNECTION Following image shows a de...

Страница 45: ...as 3 positions Plunger pulled The frontal door is open and a trained technician has pulled the plunger The Charge Point will work as usual Plunger not pushed The frontal door is open The Charge Point...

Страница 46: ...om E mail circontrol circontrol com 8 4 1 WIRING Following image shows a detailed schematic of the connections of the tamper in the CCL1 MINI PCB refer to 8 4 2 section for more details COM 2 M1 8 4 2...

Страница 47: ...1 45 Web www circontrol com E mail circontrol circontrol com 8 5 INTERFACE RGB BEACON LED CONVERTER BOARDS 29 Interface LED is composed by two boards one for each Charge Point plug inlet 8 5 1 LED BOA...

Страница 48: ...elona Tel 34 937 362 940 Fax 34 937 362 941 46 Web www circontrol com E mail circontrol circontrol com 8 5 2 LED BOARD WIRING CONNECTION TO CCL1 MINI Image below shows a basic scheme of the LED beacon...

Страница 49: ...ongoing Charging transaction starts when a user that has been authorized through the RFID plugs the EV connector in the Charge Point The charging transaction continues even if the EV passes to state B...

Страница 50: ...EVICES CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 48 Web www circontrol com E mail circontrol circontrol com This system locks the connector into the...

Страница 51: ...G SYSTEM WITH MONOSTABLE CONTROL The locking system without shutter works with monostable control 9 1 2 1 WIRING CONNECTION Following image shows a detailed schematic of the connections Please refer t...

Страница 52: ...e connections Please refer to TECHNICAL DATA section for more details LK A LK A SH1A SH2A Ethernet cable BLOCK SYSTEM MODE 3 9 2 PLUG SHUTTER 8 9 The Charge Point plugs have electrical active parts wh...

Страница 53: ...ion of one plug type 2 IEC 62196 2 and one plug CEE 7 3 for each line of power However it can only be used simultaneously one of the two plugs per line of power Following image shows a detailed schema...

Страница 54: ...Sinusoidal alternating currents and pulsating residual direct currents Sinusoidal alternating currents up to 1 kHz Direct currents Properties Operating temperature 25 55 C Dimensions 6 5 DIN modules W...

Страница 55: ...lay Restart Delay Restart Delay Restart 3 sec 10 sec 20 sec 20 sec 180 sec 60 sec 9 5 1 3 RESTART IN CASE OF BLOCKING In case of blocking of the unit the re start sequence is 1 Put the mode selector s...

Страница 56: ...ed by an MCB self reclosing as a mechanical disconnector and an earth leakage relay as an RCD Earth leakage relay MCB self reclosing The tables of technical specifications of the MCB and the Earth Lea...

Страница 57: ...mm Test and Reset T R buttons Signalling LED Power supply voltage Leakage trip Mechanical Features Operating temperature 10 50 C Weight 380 g Terminal dimensions 1 1 5 mm2 Electrical features Operatin...

Страница 58: ...ON Following image shows a detailed schematic of the connections to the CCL1 MINI Please refer to TECHNICAL DATA section for more details A1 A2 15 16 18 K08 4 7 A1 A2 Q03 1 LKA COM MCB self reclosing...

Страница 59: ...The RCD Type B self reclosing is composed by a pilot self reclosing RCD 9 5 3 1 TECHNICAL CHARACTERISTICS A table of technical specifications of the RCD Type B is shown below 9 5 3 2 ELECTRICAL DIAGRA...

Страница 60: ...LKA LKB 9 6 SURGE PROTECTION 21 23 The surge protection has the capacity of discharging induced voltage surges Suitable for the second level of protections in the supply distribution panels in which T...

Страница 61: ...t 8 20 L PE In 20 kA Response time L PE tA L PE 25 ns Voltage protection level L PE at In Up L PE 1 3 kV Remote indication Yes 9 6 2 FUSE AS A SPAREPART The fuses that are in the surge protection devi...

Страница 62: ...ircontrol com The input terminals of the power supply are designed to allow the surge protection circuit to be in parallel with the main circuit 9 6 4 CCL1 MINI WIRING Following image shows a detailed...

Страница 63: ...composed by three components which are used to avoid any vandal actions against the plugs or the electric parts Anti vandal Door Electromagnet Doors remain closed while the electromagnet circuit is ac...

Страница 64: ...com E mail circontrol circontrol com Power supply Power supply 24 Vdc This power supply converts the 230Vac voltage to 24Vdc to power the electromagnetic circuit Check output voltage at every Charge...

Страница 65: ...etailed schematic of the connections Please refer to 9 7 2 section for the connection to the CCL1 MINI PCB or to TECHNICAL DATA section for more details A1 A2 A1 A2 K08 1 K08 2 Led indicator Plug B Le...

Страница 66: ...feature is a lock key system to avoid the Charge Point to be opened by non authorized personnel The Charge Point lock system includes a regular key to open it Therefore only the person who has the ke...

Страница 67: ...ce the isolation rubber as follows on the anti vandal lock 4 Place the anti vandal lock and assemble it with the Tongue Groove Pliers 5 Final position must be like in the picture below otherwise it wi...

Страница 68: ...eb www circontrol com E mail circontrol circontrol com UNLOCKED LOCKED 8 Try the functionality You may need to adjust the position of the metallic piece in the door upwards or downwards 9 Try function...

Страница 69: ...ED SETTINGS 10 1 CHARGE POINT MAXIMUM CURRENT OUTPUT In case that the power supplied to the Charge Point is lower than the power that can be supplied by the Charge Point the Charge Point can limit the...

Страница 70: ...follow the steps below STEP ACTION 1 Set the IP address of the Charge Point IP address shall be previously assigned using IPSetup 2 Select Load management at General menu 3 Change the Status from disa...

Страница 71: ...MAXIMUM CURRENT OUTPUT FOR EACH PLUG In case that the power supplied to the Charge Point is lower than the power that can be supplied by the Charge Point the Charge Point can limit the maximum out pu...

Страница 72: ...ously assigned using IPSetup 2 Click on Connect button 3 Select the desired plugs to modify the current value By default all plugs are selected 4 Set the new current value to apply on each plug 5 Clic...

Страница 73: ...t to the central system Select this option when OCPP is activated in the Charge Point Plug sends an authorization request for each plug that is in available status In order to change from one to anoth...

Страница 74: ...s in software and installed components ERROR DRIVER COM One or more devices are not communicating correctly ERROR TAMPER Tamper activated Charge Point detects its own door opened ERROR RCD Outlet A or...

Страница 75: ...onent settings in software and installed components SOLUTION Obtain the latest firmware version of CCL1 MINI form Circontrol Expert Area Update the firmware version of the CCL1 MINI through the web se...

Страница 76: ...nication error is intermittent it could be caused by a protection earth issue In that case the electric noise of the PE wires may affect the communication wires In order to solve it separate as much a...

Страница 77: ...osition If the tamper switch is in Plunger pulled position and the error continue check the wiring For further information please refer to TAMPER SWITCH 18 section 12 1 4 ERROR RCD CONCEPT Outlet A or...

Страница 78: ...onnected to the Central System Otherwise if the message shown is Registering CB in the CS failed then check following list of errors 12 2 1 Connect failed in tcp_connect Example Sep 7 08 55 15 none us...

Страница 79: ...ed with the size of the messages sent from the Charge Point I could be in the SIM card side on in the CS This filter cause that the message or part of the message is not sent to the CS therefore infor...

Страница 80: ...int 12 2 6 SSL TLS error Example Sep 7 08 55 15 eds user err ocpp1 5 Initializing CS client 30 SOAP ENV Server SOAP ENV Server SSL TLS error Common causes HTTPS URL s requires a certificate that shall...

Страница 81: ...bedded modem Check with the SM card provider if the SIM card is activated in some cases Roaming is required too 12 2 9 No Data get host by name failed in tcp_connect Example Oct 19 12 56 41 raption us...

Страница 82: ...Charge Point side The host URL introduced is not correct Check it in the OCPP configuration Check if embedded the modem is connected to the network Otherwise check modem parameters some cellular prov...

Страница 83: ...erformance of the Charge Point and keep it in the best conditions throughout its useful lifetime This section specifies how to perform the preventive maintenance its frequency and the components that...

Страница 84: ...s per day Components inspection 10 000h 20 000h 30 000h 40 000h 50 000h 60 000h 70 000h Contactors MCB Wear check inspection and Preventive maintenance lists are in next section and available in Circo...

Страница 85: ...erator Ticket n Maintenance Hired Contract n Contractor Maintenance Information PREVENTIVE MAINTENANCE AC CHARGE POINTS Body and Fastening N Description Status 1 Fastening verification 2 Accuracy of t...

Страница 86: ...of the MCB and RCD protections according to the product specifications 3 Neutral Ground Status Input Voltage check in Phase 1 Input Voltage check in Phase 2 Input Voltage check in Phase 3 Input Volta...

Страница 87: ...ration of the network analysers 2 Setup of the date time and language 3 Schuko Type1 Type2 Adjustment of the output power according to the maximum power supported by the supply connection 4 Verificati...

Страница 88: ...trol com Functionality Test N Description Status 1 Schuko Type 1 Type 2 LED Display LED Display LED Display Stand by Charging Ventilation Pilot Signal Ground Door Alarm 2 Heater activation 3 Ventilati...

Страница 89: ...Circontrol Staff Client Operator Address Charge Point Details N Description Date Status 1 Unit Updated Previously YES NO 2 Unit Repaired Previously YES NO 3 Limit Activated YES NO 4 Power Load Managem...

Страница 90: ...NOK 15 Accuracy of the level calibration OK NOK 16 Roof Cover Verification OK NOK 17 Blowing and hoovering of the inside OK NOK 18 Verification of the isolation rubbers OK NOK Comments External Compo...

Страница 91: ...eck in Phase 1 OK NOK Input Voltage check in Phase 2 OK NOK Input Voltage check in Phase 3 OK NOK Input Voltage check between Neutral and Ground OK NOK Comments Verification of the internal electrical...

Страница 92: ...ng to the maximum power supported by the supply connection Indicate value OK NOK 45 Configuration of the local network and 3G communications OK NOK 46 Verification of the firmware and application OK N...

Страница 93: ...A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 91 Web www circontrol com E mail circontrol circontrol com Commissioning Acceptance Charge Point Client s Comments Sig...

Страница 94: ...DESFire EV1 ISO 18092 ECMA 340 NFC 13 56MHz RFID Legic reader optional LEGIC Advant LEGIC Prime ISO14443 A B compatible to part 4 MIFARE DESFireEV13 MIFARE Plus S X3 MIFARE Pro X3 MIFARE SmartMX3 SLE...

Страница 95: ...0VAC Three phase CHARGE SYSTEM PLUG A PLUG B Mode 3 IEC 61851 Mode 3 IEC 61851 PROTECTIONS PLUG A PLUG B MCB Curve C 40A 40A RCD Type A 30mA 30mA SOCKET OUTLETS 2 x Type 2 UNE EN 62196 1 lock system 1...

Страница 96: ...e 230VAC Single phase CHARGE SYSTEM PLUG A PLUG B Mode 1 IEC 61851 Mode 1 IEC 61851 PROTECTIONS PLUG A PLUG B MCB Curve C 16A 16A RCD Type A 30mA 30mA SOCKET OUTLETS 2 x CEE 7 3 14 5 MODEL TM INPUT In...

Страница 97: ...AC voltage 400VAC Three phase CHARGE SYSTEM PLUG A Mode 3 IEC 61851 PROTECTIONS PLUG A MCB Curve C 40A RCD Type A 30mA SOCKET OUTLET 1 x Type 2 UNE EN 62196 1 lock system 14 7 MODEL C63 INPUT Input v...

Страница 98: ...circontrol com 14 8 MODEL C63 one INPUT Input voltage 400VAC Three phase Nominal input current 63A Nominal input power 44kW Input frequency 50 60Hz OUTPUTS PLUG A Rated output current 63A Rated outpu...

Страница 99: ...Input frequency 50 60Hz OUTPUTS PLUG A PLUG B TYPE 2 CEE 7 3 TYPE 2 CEE 7 3 Rated output current 32A 16A 32A 16A Rated output 22kW 3 6kW 22kW 3 6kW Output AC voltage 400VAC Three phase 230VAC Single...

Страница 100: ...Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 98 Web www circontrol com E mail circontrol circontrol com 15 WIRING DI...

Страница 101: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 99 Web www circontrol com E mail circontrol circont...

Страница 102: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 100 Web www circontrol com E mail circontrol circont...

Страница 103: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 101 Web www circontrol com E mail circontrol circont...

Страница 104: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 102 Web www circontrol com E mail circontrol circont...

Страница 105: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 103 Web www circontrol com E mail circontrol circont...

Страница 106: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 104 Web www circontrol com E mail circontrol circont...

Страница 107: ...eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 105 Web www circontrol com E mail circontrol circontrol com 15 2...

Страница 108: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 106 Web www circontrol com E mail circontrol circont...

Страница 109: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 107 Web www circontrol com E mail circontrol circont...

Страница 110: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 108 Web www circontrol com E mail circontrol circont...

Страница 111: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 109 Web www circontrol com E mail circontrol circont...

Страница 112: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 110 Web www circontrol com E mail circontrol circont...

Страница 113: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 111 Web www circontrol com E mail circontrol circont...

Страница 114: ...eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 112 Web www circontrol com E mail circontrol circontrol com 15 3M...

Страница 115: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 113 Web www circontrol com E mail circontrol circont...

Страница 116: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 114 Web www circontrol com E mail circontrol circont...

Страница 117: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 115 Web www circontrol com E mail circontrol circont...

Страница 118: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 116 Web www circontrol com E mail circontrol circont...

Страница 119: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 117 Web www circontrol com E mail circontrol circont...

Страница 120: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 118 Web www circontrol com E mail circontrol circont...

Страница 121: ...Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 119 Web www circontrol com E mail circontrol circontrol co...

Страница 122: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 120 Web www circontrol com E mail circontrol circont...

Страница 123: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 121 Web www circontrol com E mail circontrol circont...

Страница 124: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 122 Web www circontrol com E mail circontrol circont...

Страница 125: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 123 Web www circontrol com E mail circontrol circont...

Страница 126: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 124 Web www circontrol com E mail circontrol circont...

Страница 127: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 125 Web www circontrol com E mail circontrol circont...

Страница 128: ...Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 126 Web www circontrol com E mail circontrol circontrol com...

Страница 129: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 127 Web www circontrol com E mail circontrol circont...

Страница 130: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 128 Web www circontrol com E mail circontrol circont...

Страница 131: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 129 Web www circontrol com E mail circontrol circont...

Страница 132: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 130 Web www circontrol com E mail circontrol circont...

Страница 133: ...Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 131 Web www circontrol com E mail circontrol circontrol co...

Страница 134: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 132 Web www circontrol com E mail circontrol circont...

Страница 135: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 133 Web www circontrol com E mail circontrol circont...

Страница 136: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 134 Web www circontrol com E mail circontrol circont...

Страница 137: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 135 Web www circontrol com E mail circontrol circont...

Страница 138: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 136 Web www circontrol com E mail circontrol circont...

Страница 139: ...Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 137 Web www circontrol com E mail circontrol circontrol com...

Страница 140: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 138 Web www circontrol com E mail circontrol circont...

Страница 141: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 139 Web www circontrol com E mail circontrol circont...

Страница 142: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 140 Web www circontrol com E mail circontrol circont...

Страница 143: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 141 Web www circontrol com E mail circontrol circont...

Страница 144: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 142 Web www circontrol com E mail circontrol circont...

Страница 145: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 143 Web www circontrol com E mail circontrol circont...

Страница 146: ...ste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 144 Web www circontrol com E mail circontrol circontrol com 1...

Страница 147: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 145 Web www circontrol com E mail circontrol circont...

Страница 148: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 146 Web www circontrol com E mail circontrol circont...

Страница 149: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 147 Web www circontrol com E mail circontrol circont...

Страница 150: ...MANUAL Poste eVolve Smart 15 WIRING DIAGRAMS PHASE II CIRCONTROL S A Innovaci 3 08232 Viladecavalls Barcelona Tel 34 937 362 940 Fax 34 937 362 941 148 Web www circontrol com E mail circontrol circont...

Страница 151: ...16 NEED HELP In case of any query or if further information is required please contact our Post Sales Department ps support circontrol com Circontrol com 34 937 362 940 34 937 362 941...

Страница 152: ......

Отзывы: