19
Shut Down Procedure
A) Shut Engine off by turning key to “
0
”
B) Set Control Panel and Mastic Control Panel rotary switch to “
OFF ”
C) Move Boom to travel position and
lock
.
D) Store wand
Additional Settings
Modifying Sealant Temperature Control Settings
The Sealant Temperature Control on your CIMLINE C1 melter has been factory set to run the
most common types of sealants. These sealants have an application temperature of 380° F
(193°C) With some sealants, it may be require a change to the controller to achieve the
appropriate application temperature. To achieve this, open the control box and alter the Sealant
Temperature Controller (top controller) by following the directions below.
Decrease
Increase
(A)
1) Press the SET button.
2) SP1 is displayed.
3) Press the SET button.
4) Current Temperature is displayed.
5) Use the arrow buttons to change to the desired temperature.
6) Press the SET button.
7) Let the controller time out. Your controller will now be changed and the updates will be
saved.