58
Mastic Mixture Ratio
There may be times when you wish to have a different mixture then what is most commonly
used. This can be easily done by changing the flow controls valves on the manifold.
See table below to set mixture ratios.
2:1 Rock to Sealant Ratio is most common for Mastic Applications
(9 on the Dial for the Rock Flow Control and 5 on the Dial for the Sealant Flow Control)
Rock:Sealant
Ratio
Sealant Flow Control
(Under main control panel)
1
2
3
4
5
6
7
8
9
Rock Flow
Control
(
Under mastic
control panel)
1
1
2
2
1
3
3 1.5 1
4
2 1.3 1
More
Sealant
5
2.5 1.7 1.3 1
6
3
2 1.5 1.2 1
Most
Common
7
2.3 1.8 1.4 1.2 1
8
2.7 2 1.6 1.3 1.1 1
More Rock
9
2.5 2 1.7 1.4 1.3 1
Содержание C1
Страница 13: ...13 Sub Control Panel Controls and Their Functions 1 2 3 4 5 6 7 8 9 10 11 12 IMLINE ...
Страница 29: ...29 Trailer Wiring Diagram Note Brake controller is required on vehicle to active the brakes on the trailer ...
Страница 31: ...31 Sealant Control Panel Wiring Diagram ...
Страница 37: ...37 Tank Burner Internal Wiring Diagram ...
Страница 39: ...39 Hydraulic Schematic For Compressor Hydraulics see Supplement manual ...
Страница 45: ...45 Sealant Plumbing Components ...
Страница 50: ...50 Mastic Mixer Assembly ...
Страница 55: ...55 Miscellaneous Parts ...