12
NOTE
:
CIMLINE recommends using the Main Control Panel in Auto
Control mode . Manual mode is provided mainly for trouble
shooting
1)
Auto/Off/Manual Switch
Auto mode,
Machine will operate from the systems preconfigured program using the
controls located on the front cover.
Off,
(center position) All systems will be off and machine will stop.
Manual
, Main switch on front cover is no longer active. The four switches below must
be used to control the melter’s operations.
2)
Controller On/Off Switch:
When this switch is on, the three controllers to the right will
be energized and they will be controlling the Diesel burner and the heated hose generator.
3)
Material Pump Seal/Off/Clean-out Switch:
When this switch is on “ Seal” , the pump will
be rotating and material will recirculate back to tank, when wand switch is activated, material
will dispense out the hose. When the switch is “Off”, the pump will not be rotating. When the
switch is on “Clean-out”, the pump will be rotating in the reverse directing and will be drawing
back any material in the plumbing or the hose.
4)
Agitator CCW/OFF/CW Switch:
This switch controls the rotation of the agitator from
counter-clockwise or Clockwise. If the switch is in the center position, the agitator will not
rotate.
5)
Low Flow Switch:
Some sealants dispense best at low flow rates (<4), if they dispense
unevenly, switch the Auto/Manual switch to Manual and place the Low flow switch to the “For
material flow Lower than 4”. This will make the material pump only rotate when the wand
trigger is pressed, resulting in more consistent dispensing.
6)
Pump LED (Green):
This LED indicates that the material has reached the preset
temperature and if the unit is running in the Auto mode, the Material pump will be pumping.
7)
Agitator LED (Green):
This LED indicates that the Heat Transfer Oil has reached the
preset temperature and if the unit is running in the Auto mode, the Agitator will be turning.
8)
Heated Hose LED (Green):
This LED indicates that the Heated Hose has reached the
preset temperature and is ready to use.
9)
Diesel Burner LED (Yellow):
This LED indicates that the Diesel Burner is on.
10)
Heated Hose Fuse:
This Slow-blow fuse is protecting the Heated Hose.
11)
Heated Hose Generator LED (Yellow):
This LED indicates that the Heated Hose
Generator is on.
12)
Sealant Temperature Controller
The control system on your CIMLINE C1 melter has
been factory set to run the most common types of materials. See page 17 to override
settings.
Sub Control Panel Controls and Their Functions
Содержание C1
Страница 13: ...13 Sub Control Panel Controls and Their Functions 1 2 3 4 5 6 7 8 9 10 11 12 IMLINE ...
Страница 29: ...29 Trailer Wiring Diagram Note Brake controller is required on vehicle to active the brakes on the trailer ...
Страница 31: ...31 Sealant Control Panel Wiring Diagram ...
Страница 37: ...37 Tank Burner Internal Wiring Diagram ...
Страница 39: ...39 Hydraulic Schematic For Compressor Hydraulics see Supplement manual ...
Страница 45: ...45 Sealant Plumbing Components ...
Страница 50: ...50 Mastic Mixer Assembly ...
Страница 55: ...55 Miscellaneous Parts ...