3-8
Turning Up the System
3930 Service Delivery Switch
Hardware Installation and Start-up Manual
009-3223-001 Standard Revision E
Copyright
©
2012-2014 Ciena
®
Corporation
January 2014
Procedure 3-1
Logging in through the Serial Console Port
Step
Action
1
Ensure that the chassis is properly rack-mounted, grounded, and installed.
2
Connect a terminal or PC running terminal emulation software to the serial
console port using the recommended cable.
Note:
The serial console port does not support connectivity to a modem.
3
If using a PC, launch the terminal emulation software.
4
At the prompt, configure the connected terminal with the following settings:
Character size = 8
Parity = None
Stop Bit = 1
Baud Rate = 9600 bps
Control = None
5
When the Hyper Terminal prompt is displayed, press
Enter
and the login
prompt is displayed. Enter the default user name and password.
username = su
password = wwp
You have logged in to the system.