6.1 Schedule of Function Parameters
6.1 Schedule of Function Parameters
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
Function
Code
Name
Setting Range
Unit
Min.
Unit
Default
Setting
Operation
Modification
6.1.7 F6 Series PID Function Parameters (Continuation...)
6.1.8 F7 Series Programmable Operation Parameters
Programmable operation
control
LED units digit PLC operation
mode selection
0: No action
1: Single cycle
2: Continuous cycle
3: Remaining the ultimate value
after single cycle
4: Wobble operation
LED tens digit PLC input mode
selection
0: Auto input
1: Input through defined multi-
function terminals
LED hundreds digit Remain
0: Auto input
1: Input through defined multi-
function terminals
LED thousands digit Remain
6.1.8 F7 Series Programmable Operation Parameters (Continuation....)
1st stage operation time
2nd stage operation time
3rd stage operation time
4th stage operation time
th
5 stage operation time
th
6 stage operation time
th
7 stage operation time
Remain
Multi-stage speed
operating direction 1
Multi-stage speed
operating direction 2
LED units digit: Stage 1 direction
0: Forward
1: Reverse
LED tens digit Stage 2 direction
0: Forward
1: Reverse
LED hundreds digit Stage 3
direction
0: Forward
1: Reverse
LED thousands digit Stage 4
direction
0: Forward
1: Reverse
LED units digit: Stage 5 direction
0: Forward
1: Reverse
LED tens digit Stage 6 direction
0: Forward
1: Reverse
LED hundreds digit Stage 7
direction
0: Forward
1: Reverse
LED thousands digit: Remain
Self-motion
Sampling cycle T
Deviation limit
Closed loop preset
frequency
Upper limit frequency
Preset frequency keep time
Sleep threshold value
Awake threshold value
Sleep/awake threshold value
detection value